Panasonic ALDP124 PCB Mount Relay 1 NO, SPST-NO ALDP124 Datenbogen

Produktcode
ALDP124
Seite von 4
LD-P (ALDP)
2
ds_61B10_0004_en_ldp: 021009D
2. Specifications
Notes:
*1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2 Wave is standard shock voltage of 
±1.2×50μs according to JEC-212-1981
*3 The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport 
Conditions” in 
REFERENCE DATA
Characteristics
Item
Specifications
Contact
Arrangement
1 Form A
Contact resistance (Initial)
Max. 100 m
Ω (By voltage drop 6 V DC 1A)
Contact material
AgNi type
Rating
Nominal switching capacity (resistive load)
5A 277V AC
Max. switching power (resistive load)
1,385VA
Max. switching voltage
277V AC
Max. switching current
5A
Min. switching capacity (reference value)*
1
100mA 5V DC
Electrical 
characteristics
Insulation resistance (Initial)
Min. 1,000M
Ω (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage 
(Initial)
Between open contacts
750 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil
4,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*
2
 
(Between contact and coil)
10,000 V (initial)
Temperature rise
Max. 30
°C 
86
°F
 (By resistive method, nominal coil voltage applied to the coil; 
contact carrying current: 5A, at 85
°C 
185
°F
)
Operate time (at nominal voltage) (at 20
°C 
68
°F
)
Max. 10 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20
°C 
68
°F
)
Max. 10 ms (excluding contact bounce time) (With diode)
Mechanical 
characteristics
Shock resistance
Functional
Min. 300 m/s
2
 (Half-wave pulse of sine wave: 11 ms; detection time: 10
μs.)
Destructive
Min. 1,000 m/s
2
 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional
10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10
μs.)
Destructive
10 to 55 Hz at double amplitude of 1.5 mm
Expected life
Mechanical (at 180 cpm)
Min. 5
×10
6
Electrical (at 20 cpm)
Min. 2
×10
5
 (5A 125V AC at rated load), Min. 10
5
 (5A 250V AC at rated load)
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature: –40
°C to +85°C 
–40
°F to +185°F
;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 
(at nominal switching capacity)
20 cpm
Unit weight
Approx. 4 g 
.14 oz
1. Max. switching power
2. Life curve
3. Coil temperature rise
Sample: ALDP112, 6 pcs.
Point measured: inside the coil
Contact current: 0 A, 5 A
10
100
10
5
1
0.1
Contact voltage, V
Contact current, A
AC resistive load
6
5
4
3
2
1
0
100
10
1
Contact current, A
125V AC resistive load
250V AC resistive load
Lif
e
×
10
4
5A*
0A*
140
120
100
80
50
40
30
20
10
Coil applied voltage, %V
T
emper
ature r
ise
°
C
*at room temperature
85
°
C 5A
85
°
C 0A
4-(1). Operate time
Sample: ALDP112, 30 pcs.
4-(2). Release time (without diode)
Sample: ALDP112, 30 pcs.
4-(3). Release time (with diode)
Sample: ALDP112, 30 pcs.
Max.
Min.
140
120
100
80
60
10
8
6
4
2
0
Coil applied voltage, %V
Oper
ate time
, ms
Max.
Min.
140
120
100
80
60
10
8
6
4
2
0
Coil applied voltage, %V
Release time
, ms
Max.
Min.
140
120
100
80
60
10
8
6
4
2
0
Coil applied voltage, %V
Release time
, ms