TE Connectivity RT314A12 PCB Mount Relay 12Vdc 16A 1 CO, SPDT 8-1393239-0 Datenbogen
![TE Connectivity](https://files.manualsbrain.com/attachments/dbd803c18d109283f440b3cbb1dff849ca94f13f/common/fit/150/50/547dc9fbf68a61e9568581c94845f8f91614b8dcfc1a6e342be5703a316d/brand_logo.jpeg)
Produktcode
8-1393239-0
Datasheet
Rev. FE1
Issued 2006/05
www.tycoelectronics.com
www.schrackrelays.com
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
change.
General Purpose Relays
2
*) With the recommended PCB hole sizes a grid
pattern from 2.5 mm to 2.54 mm can be used.
pattern from 2.5 mm to 2.54 mm can be used.
Power PCB Relay RT1 bistable
(Continued)
PCB layout / terminal assignment
Bottom view on solder pins
16 A, pinning 5 mm
1 CO contact
a) Indicated contact position during or after coil
energization with reset voltage.
b) for 2 coil version only
S0418-CM
S0163-CI
S0272-BC
Dimensions
a)
Coils operation
Version
Version
1 coil
2 coils
Coil terminals
A1
A2
A1
A3
A2
Pull-in
+
-
+
-
Reset
-
+
-
+
Contact position not defined at delivery
Insulation
Dielectric strength coil-contact circuit
5000 V
rms
open contact circuit
1000 V
rms
Clearance / creepage coil-contact circuit
W 10 / 10 mm
Material group of insulation parts
W IIIa
Tracking index of relay base
PTI 250 V
Insulation to IEC 60664-1
Type of insulation coil-contact circuit
reinforced
open contact circuit
functional
Rated insulation voltage
250 V
Pollution degree
3
2
Rated voltage system
240 V
400 V
Overvoltage category
III
Other data
RoHS - Directive 2002/95/EC
compliant as per product date code 0413
Flammability class according to UL94
V-0
Ambient temperature range 1 coil
-10...+85°C
2 coils
-40...+85°C
Operate- / reset time
typ 5 / 4 ms
Bounce time NO / NC contact
typ 1 / 3 ms
Vibration / shock resistance (function) opening NC contact
3 / 5 g
opening closed NO contact
6 / 15 g
Shock resistance (destruction)
100 g
Category of protection
RTII - flux proof
Mounting
pcb or on socket *
)
Mounting distance
0 mm
Resistance to soldering heat flux-proof version
270 °C / 10 s
Relay weight
14 g
Packaging unit 1 coil
20 / 500 pcs
2 coils
100 pcs
*
)
socket available for 1 coil version only, see Accessories
Accessories
For 1 coil version, details see datasheet
Accessories Power Relay RT