Panasonic ALF1P24 PCB Mount Relay 24Vdc 1 NO, SPST-NO ALF1P24 Datenbogen

Produktcode
ALF1P24
Seite von 3
LF (ALF)
1
ds_61162_0000_en_lf: 061006J
SPECIFICATIONS
20A POWER RELAY FOR 
HOME APPLIANCES
LF RELAYS (ALF)
VDE
TMP type
PCB type
mm 
inch
30.1
1.185
23.3
.917
15.7
.618
23.3
.917
30.1
1.185
15.7
.618
FEATURES
1. Ideal for compressor and inverter 
loads
1) Compressor load: 20A 250V AC
2) Inverter load: 20A 100V AC, 
                          10A 200V AC
2. High insulation resistance
• Creepage distance and clearances 
between contact and coil;
Creepage Min. 9.5mm 
.374inch
/
Clearance Min. 8mm 
.315inch
• Surge withstand voltage: Min. 10,000V
3. “PCB” and “TMP” types available
4. Conforms to the various safety 
standards:
UL/CSA, TÜV, VDE approved
Contact
Coil
#1 This value can change due to the switching frequency, environmental conditions, 
and desired reliability level, therefore it is recommended to check this with the 
actual load.
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as “Initial breakdown voltage” section.
*
2
Detection current: 10mA
*
3
Wave is standard shock voltage of 
±1.2 × 50μs according to JEC-212-1981
*
4
Excluding contact bounce time.
*
5
Half-wave pulse of sine wave: 11 ms; detection time: 10 
μs
*
6
Half-wave pulse of sine wave: 6 ms
*
7
Detection time: 10 
μs
*
8
Refer to 6. Conditions for operation, transport and storage mentioned in 
Characteristics
Arrangement
1 Form A
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
100 m
Ω
Contact material
AgSnO
2
 type
Rating
(resistive load)
Nominal switching 
capacity
20 A 250V AC
Max. switching 
power
6,250 V A
Max. switching 
voltage
250V AC
Max. switching 
current
25 A
Min. switching 
capacity
#1
100 mA, 5 V DC
Expected life
(min. operations)
Mechanical
(at 180 cpm)
× 10
6
Electrical 
(at 20 cpm)
(Resistive load)
10
5
Nominal operating power
900 mW
Max. operating speed
(at rated load)
20 cpm
Initial insulation resistance*
1
Min. 1,000 M
Ω (at 500 V DC)
Initial 
breakdown 
voltage*
2
Between open contacts
1,000 Vrms for 1 min.
Between contacts and 
coil
5,000 Vrms for 1 min.
Surge voltage between contact and 
coil*
3
Min. 10,000 V
Operate time*
4
 (at nominal voltage)
Max. 20 ms (at 20°C 
68°F
)
Release time (without diode)*
4
(at nominal voltage)
Max. 15 ms (at 20°C 
68°F
)
Temperature rise
(at nominal voltage)
Max. 45
°C
(resistance method, contact 
current 20 A, rated coil 
voltage, 60
°C 140°F)
Shock resistance
Functional*
5
Min. 100 m/s
2
{10 G}
Destructive*
6
Min. 1,000 m/s
2
{100 G}
Vibration resistance
Functional*
7
10 to 55Hz
at double amplitude of 1.5mm
Destructive
10 to 55Hz
at double amplitude of 1.5mm
Conditions for operation, 
transport and storage*
8
(Not freezing and 
condensing at low 
temperature)
Ambient 
temp.
–40
°C to +60°C
–40
°F to +140°F
Humidity
5 to 85% R.H.
Unit weight
Approx. 23 g .81 oz
TYPICAL APPLICATIONS
• Air conditioner
• Refrigerators
• OA equipment
ORDERING INFORMATION
Product Name
LF
Contact arrangement
Terminal shape
Coil voltage, V DC
1: 1 Form A
Note: Standard packing; Carton: 50 pcs. Case 200 pcs.
UL/CSA,VDE, TÜV approved type is standard.
T: TMP type
P: PCB type
05: 5      12: 12
06: 6      18: 18
09: 9      24: 24
Ex.
A
LF
1
T
12