Panasonic TQ2L25 PCB Mount Relay 5V 2 CO, DPDT TQ2L25 Datenbogen

Produktcode
TQ2L25
Seite von 7
TQ
1
ds_61020_0001_en_tq: 101006J
SPECIFICATIONS
LOW PROFILE 
2 FORM C RELAY
TQ RELAYS
9
.354
26.7
1.051
5
.197
+0.4
Ð0.2
+.016
Ð.008
mm 
inch
9
.354
14
.551
5
.197
+0.4
Ð0.2
+.016
Ð.008
FEATURES
• High sensitivity:
2 Form C: 140 mW power consumption (single side stable type)
4 Form C: 280 mW power consumption (single side stable type)
• Surge voltage withstand: 1500 V FCC Part 68
• Sealed construction allows automatic washing
• Self-clinching terminal also available
• M.B.B. contact types available
Contact
Note:
#1 This value can change due to the switching frequency, environmental conditions, 
and desired reliability level, therefore it is recommended to check this with the 
actual load. (SX relays are available for low level load switching [10V DC, 10mA 
max. level])
Characteristics
Standard 
(B.B.M) type
M.B.B.type
Arrangement
2 Form C
4 Form C
2 Form D
Initial contact resistance, max. 
(By voltage drop 6 V DC 1A)
50 m
Ω
Contact material
Gold-clad silver
Rating
Nominal switching capacity 
(resistive load)
1 A 30 V DC 
0.5 A 125 V AC
1 A 30 V 
DC
Max. switching power 
(resistive load)
30 W, 62.5 V A
30 W
Max. switching voltage
110 V DC, 125 V AC
110 V DC
Max. switching current
1 A
Min. switching capacity 
(Reference value)
#1
10 
μA 10 mV DC
Nominal 
operating 
power
Single side stable
140 mW 
(3 to 12 V DC)
200 mW 
(24 V DC)
300 mW 
(48 V DC)
280 mW 
(3 to 24 V DC) 
400 mW 
(48 V DC)
200 mW
1 coil latching
100 mW 
(3 to 12 V DC)
150 mW 
(24 V DC)
200 mW
2 coil latching
200 mW 
(3 to 12 V DC)
300 mW 
(24 V DC)
400 mW
Expected 
life (min. 
opera-
tions)
Mechanical (at 180 cpm)
10
8
 10
7
 
Electrical 
(at 20 cpm) 
(1 A 30 V 
DC resistive)
1 A 30 V DC 
resistive
2
×10
5
 10
5
0.5 A 125 V AC 
resistive
10
5
 
Standard 
(B.B.M) type
M.B.B.type
Initial insulation resistance*
1
Min. 1,000 M
Ω (at 500 V DC)
Initial 
breakdown 
voltage
Between open 
contacts
750 Vrms for 1 min. 
(Detection current: 
10 mA)
300 Vrms for 1 min. 
(Detection current: 
10 mA)
Between contact 
and coil
1,000 Vrms for 1 min. 
(Detection current: 10 mA)
Between contact 
sets
1,000 Vrms for 1 min. 
(Detection current: 10 mA)
FCC surge voltage between open 
contacts
1,500 V
Operate time [Set time]*
3
 
(at 20
°C)
Max. 3 ms [Max. 3 ms]
Release time [Reset time]*
4
 
(at 20
°C)
Max. 3 ms [Max. 3 ms]
M.B.B. time*
8
Min. 10 
μs.
Temperature rise*
2
 (at 20
°C)
Max. 50
°C
Shock resistance
Functional*
5
Min. 490 m/s
2
 {50G}
Destructive*
6
Min. 980 m/s
2
 {100G}
Vibration 
resistance
Functional*
7
176.4 m/s
2
 {18G}, 10 to 55 Hz 
at double amplitude of 3 mm
Destructive
294 m/s
2
 {30G}, 10 to 55 Hz 
at double amplitude of 5 mm
Conditions for 
operation, trans-
port and storage*
9
(Not freezing and 
condensing at low 
temperature)
Ambient 
temperature
–40
°C to +70°C 
–40
°F to +158°F
–40
°C to +50°C 
–40
°F to +122°F
Humidity
5 to 85% R.H.
Unit weight
2 Form C:
Approx. 1.5 g 
.053 oz
4 Form C:
Approx. 3 g 
.106 oz.
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as “Initial breakdown voltage” section.
*
2
By resistive method, nominal voltage applied to the coil; contact carrying current: 
1 A.
*
3
Nominal voltage applied to the coil, excluding contact bounce time.
*
4
Nominal voltage applied to the coil, excluding contact bounce time without diode.
*
5
Half-wave pulse of sine wave: 11 ms; detection time: 10 
μs.
*
6
Half-wave pulse of sine wave: 6 ms.
*
7
Detection time: 10 
μs.
*
8
M.B.B. time:
*
9
Refer to 6. Conditions for operation, transport and storage mentioned in 
.
Measuring
condition
Min. 10 
μs
500 
Ω
5 V DC