Panasonic JQ1AB12F PCB Mount Relay 12V 1 NO, SPST-NO JQ1AB12F Datenbogen

Produktcode
JQ1AB12F
Seite von 5
JQ
2
ds_61144_0000_en_jq: 041206D
Characteristics
Remarks
*
Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as “Initial breakdown voltage” section
*
2
Detection current: 10 mA
*
3
Wave is standard shock voltage of 
±1.2 × 50μs according to JEC-212-1981
*
4
Excluding contact bounce time
*
5
Measured conditions
*
6
Half-wave pulse of sine wave: 11ms; detection time: 10
μs
*
7
Half-wave pulse of sine wave: 6ms
*
8
Detection time: 10
μs
*
9
 Refer to 6. Conditions for operation, transport and storage mentioned in 
*
10
When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 
33.8°F
 with 
20°C
68°F
 as a reference) and use a coil impressed voltage that is within the maximum allowable voltage range.
TYPICAL APPLICATIONS
• Air conditioners
• Refrigerators
• Microwave ovens
• Heaters
ORDERING INFORMATION
Max. operating speed
20 cpm
Initial insulation resistance*
1
Min. 1,000 M
Ω at 500 V DC
Initial breakdown voltage*
2
Between open contacts
1a: 1,000 Vrms for 1 min.
1c: 750 Vrms for 1 min.
Between contacts and coil
4,000 Vrms for 1 min.
Surge voltage between contact and coil*
3
8,000 V
Operate time*
4
 (at nominal voltage)
Max. 20 ms
Release time*
4
 (at nominal voltage)(without diode)
Max. 10 ms
Temperature rise*
5
Max. 45
°C
Shock resistance
Functional*
6
Min. 294 m/s
2
 {30 G}
Destructive*
7
Min. 980 m/s
2
 {100 G}
Vibration resistance
Functional*
8
98 m/s
2
 {10 G}, 10 to 55 Hz at double amplitude of 1.6 mm
Destructive
117.6 m/s
2
 {12 G}, 10 to 55 Hz at double amplitude of 2.0 mm
Conditions for operation, transport and storage*
9
(Not freezing and condensing at low temperature)
Ambient temp.*
10
–40
°C to +85°C 
–40
°F to +185°F
Humidity
5 to 85% R.H.
Unit weight
Approx. 7 g .
25 oz
Standard type
Resistive, nominal voltage applied to the coil. Contact carrying current: 5 A, at 70
°C 
158°F
High capacity type
Resistive, nominal voltage applied to the coil. Contact carrying current: 10 A, at 70
°C 
158°F
Contact
arrangement
1a: 1 Form A
1: 1 Form C
Nil: Standard
P: High capacity
5, 6, 9, 12, 18, 24, 48* V
Contact capacity
Nil: Class E coil insulation
B: Class B coil insulation
Coil insulation class
F: AgSnO
2
 type
Contact material
Coil voltage (DC)
UL/CSA, VDE, SEMKO approved type is standard.
* Available only for 1 Form C type
1a
P
B
Ex.    JQ
12
F
V