12.Failure correction notes
If you are not able to clear the failure condition, please contact Mean Well or 
any of our distributors for repair service.
Status
Unable to 
charge
the battery
LED indicator 
does not turn 
Green after a 
long charging 
period
Possible reasons
ON/OFF switch in the OFF position
Switch to the ON position
Reconnect using the 
right polarity
Use battery with the 
correct voltage
Make sure input source 
is between 90~264VAC
Replace with a new 
battery
Replace with suitable 
wire gauge 
Battery reverse polarity
Battery with higher voltage is 
connected
Input AC voltage is too low
Battery exceeded lifespan or 
damaged
Output cables are too thin
Solutions
11.Recommended wire specification
Note: Please install in accordance with the table above. Wire gauge should be no 
smaller than No. 18 AWG/3C. Socket type restricted to 15A, 125V (NEMA 5-15P) 
or 15A, 250V(NEMA 6-15P) with power cord length ranging from 1.8 meters 
to 10 meters.
Installation
Desktop, counter top, chassis 
box (mobile)
SP-2, SPE-2, SPT-2,SV,SVE,SVT
10ft (3 meter)
Grounded, fixed in place 
(not mobile)
Not specified
Safety rating
Maximum length
S, SE, SO, SP-3, SPT-3, ST, STO,
SJ, SJE, SJO, SJT, SJTO
2.Batteries in parallel
W h e n 2 b a t t e r i e s a re c o n n e c t e d i n p a ra l l e l , v o l t a g e r e m a i n s t h e s a m e a n d t h e 
capacity (Ah) doubles. For example, 2 x 12V 100Ah batteries connected in parallel 
= 12V 200Ah.
+
+
Battery
Battery
-
-