TE Connectivity Connector receptacle AWG (min.): 28 AWG max.: 24 Brass 1 pc(s) 66683-4 Informationshandbuch

Produktcode
66683-4
Seite von 16
108-40005
Test Description
Requirem ent
Procedure
Tem perature rise vs current.
30°C m axim um  tem perature rise at
specified current.
EIA-364-70, Method 1.
Stabilize at a single current level
until 3 readings at 5 m inute intervals
are within 1°C.
See Figure 4.
MECHANICAL
Vibration, random .
No discontinuities of 1 m icrosecond
or longer duration.
See Note.
EIA-364-28, Test Condition V,
Condition F.
Subject m ated specim ens to 20.71
G's rm s between 50 to 2000 Hz.
Fifteen m inutes in each of 3
m utually perpendicular planes.
See Figure 5.
Mechanical shock.
No discontinuities of 1 m icrosecond
or longer duration.
See Note.
EIA-364-27, Method A.
Subject m ated specim ens to 50 G's
half-sine shock pulses of 11
m illiseconds duration. Three shocks
in each direction applied along 3
m utually perpendicular planes, 18
total shocks.
See Figure 5.
Durability.
See Note.
EIA-364-9.
Mate and unm ate gold flash
specim ens for 100 cycles, and 30
ìin gold specim ens for 500 cycles
at a m axim um  rate of 200 cycles
per hour.
Mating force.
                       W ithout       W ith
                          Ground Indents
Size  Posn     (N [lbf] m axim um )
   1       9      12.5 [2.8]    133.4 [30]
   2      15     20.9 [4.7]    146.8 [33]
   3      25     34.7 [7.8]    164.6 [37]
   4      37     51.6 [11.6]  177.9 [40]
   5      50     69.4 [15.6]  195.7 [44]
EIA-364-13.
Measure force necessary to m ate
specim ens at a m axim um  rate of
25.4 m m  [1 in] per m inute.
Unm ating force.
                        W ithout      W ith
                          Ground Indents
Size  Posn      (N [lbf] m axim um )
   1       9      12.5 [2.8]    133.4 [30]
   2      15     20.9 [4.7]    146.8 [33]
   3      25     34.7 [7.8]    164.6 [37]
   4      37     51.6 [11.6]  177.9 [40]
   5      50     69.4 [15.6]  195.7 [44]
EIA-364-13.
Measure force necessary to unm ate
specim ens at a m axim um  rate of
25.4 m m  [1 in] per m inute.
Contact insertion force.
13.3 N [3 lbf] m axim um  per contact. EIA-364-5.
Measure force necessary to insert
contact into housing.
Figure 1 (continued)
Rev F
3 of 10