TE Connectivity Split sleeve 1 pc(s) 3-747579-4 Informationshandbuch
Produktcode
3-747579-4
108-40005
3.2.
Material
Materials used in the construction of this product shall be as specified on the applicable product
drawing.
drawing.
3.3.
Ratings
!
Voltage: 250 volts AC
!
Current: Fully loaded and energized connectors, see Figure 4
•
•
18 AW G: 3.1 am peres
•
22 AW G: 2.0 am peres
•
28 AW G: 1.2 am peres
!
Tem perature: -55 to 105°C
3.4.
Perform ance and Test Description
Product is designed to m eet the electrical, m echanical and environm ental perform ance requirem ents
specified in Figure 1. Unless otherwise specified, all tests are perform ed at am bient tem perature.
specified in Figure 1. Unless otherwise specified, all tests are perform ed at am bient tem perature.
3.5.
Test Requirem ents and Procedures Sum m ary
Test Description
Requirem ent
Procedure
Exam ination of product.
Meets requirem ents of product
drawing and Application
Specification 114-40030.
drawing and Application
Specification 114-40030.
EIA-364-18.
Visual and dim ensional (C of C)
inspection per product drawing.
Visual and dim ensional (C of C)
inspection per product drawing.
Final exam ination of product.
Meets visual requirem ents.
EIA-364-18.
Visual inspection.
ELECTRICAL
Low level contact resistance.
15 m illiohm s m axim um .
EIA-364-23.
Subject specim ens to 100
m illiam peres m axim um and 20
m illivolts m axim um open circuit
voltage.
See Figure 3.
m illiam peres m axim um and 20
m illivolts m axim um open circuit
voltage.
See Figure 3.
Contact resistance, specified
current.
current.
W ire Test Resistance
Size Current Maxim um
(AW G) (am peres) (m illiohm s)
18 3.1 15
20 2.4 15
22 2.0 15
24 1.6 15
26 1.3 15
28 1.2 15
Size Current Maxim um
(AW G) (am peres) (m illiohm s)
18 3.1 15
20 2.4 15
22 2.0 15
24 1.6 15
26 1.3 15
28 1.2 15
EIA-364-6.
Measure potential drop of m ated
contacts assem bled in housing.
Calculate resistance.
See Figure 3.
Measure potential drop of m ated
contacts assem bled in housing.
Calculate resistance.
See Figure 3.
Insulation resistance.
5000 m egohm s m inim um initial.
500 m egohm s m inim um final.
500 m egohm s m inim um final.
EIA-364-21.
Test between adjacent contacts of
unm ated specim ens.
Test between adjacent contacts of
unm ated specim ens.
W ithstanding voltage.
One m inute hold with no breakdown
or flashover. 0.5 m illiam pere
m axim um leakage current.
or flashover. 0.5 m illiam pere
m axim um leakage current.
EIA-364-20, Condition I.
1000 volts AC at sea level.
Test between adjacent contacts of
unm ated specim ens.
1000 volts AC at sea level.
Test between adjacent contacts of
unm ated specim ens.
Figure 1 (continued)
Rev F