Arcolectric C 1553 VB NAB Rocker Switch, 16 A C 1553 VB NAB Datenbogen
Produktcode
C 1553 VB NAB
26
A
Softline
Matt
B
Splashproof
(with Arcshield)
V
Curved
W
Splashproof
(with Arcshield)
P
Lit window
Matt
X
Two colour
Matt
F
Flat lens
Gloss (0480 only)
A
Softline lens
Matt (0480 only)
as F but with raised profile
TERMINAL FUNCTION ROCKER BODY PRINT, COLOUR, VOLTAGE ETC
C 1553 A L ---
1550 Series
16(4)A 250Vac T125
UL CSA 16A 250Vac, (2 posn) 250Vac 1hp, 125Vac 1/2hp,
(3 posn) 250 Vac 1/2hp, 125Vac 1/4hp. UL 85˚C, file E45221, CSA file LR10990
Inrush 36A to EN61058-1 & 20A 28Vdc
1350 series
16(4)A 250Vac T85 1E4 (10,000 Ops.)
On request 16(6)A 250Vac T125 5E4 (50,000 Ops.) & 150A Inrush to IEC 65
UL CSA 20A 250Vac 1hp, 125Vac 1/2hp
UL 72Vdc 7A, 36Vdc 14A. UL 85˚C, file E45221, CSA file LR10990
20A 28Vdc
3mm contact gap except if marked µ. Technical data on pages 4 & 5 (switches), 66 (indicators)
ON - OFF
1550 Standard & 1350 Hi Inrush Switches
150A to IEC65 and 16A 250Vac
ROCKER
FUNCTION
Approvals & ratings vary with function
On Off Switches - ON when pressed over terminal 1
TERMINAL
Hi Inrush
1350
♦
C
6.3 x 0.8
H
4.8 x 0.8
*
K
2.8 x 0.8
*
T
Solder
U
Right angle T Solder (Not DP)
X
PCB 0.8Sq
*
*
Contact factory for details on 1350 series
9.1
7.0
Ø2.1
9.1
9.1
2.0
1.2
3.2
Ø2.1
9.1
4.0
1 2
3
4 5
6
In house test
In house test
Standard
1550
♦
ON - OFF
(momentary ON)
1551
HP rating N/A
ON - OFF
(momentary OFF)
1552
HP rating N/A
ON - OFF
Lit
1353
♦
Not W, X or B rocker
1553
♦
Not W, X or B rocker
ON - ON
1560
♦
µ
ON - ON
(momentary 1 side)
1561
µ
HP rating N/A
2 Circuit
ON - ON
1562
µ
In house tests only
ON - OFF - ON
1570
♦
µ
125V & 250V 1/2 HP
H terminal rated T100 only
ON - OFF - ON
(momentary 1 side)
1571
µ
HP rating N/A
H terminal rated T100 only
ON - OFF - ON
(momentary 2 sides)
1572
µ
HP rating N/A
H terminal rated T100 only
3 position selective
OFF - A - A+B
1484
µ
In-house tested to 10(3)A 250Vac
3 position selective
A - B - C
(link not supplied)
1487
µ
In-house tested to 10(3)A 250Vac
Indicator
Technical data on page 66
0480
X terminal N/A
1
2
4
5
3
6
1
2
4
5
3
6
1
2
4
5
3
6
1
2
4
5
3
6
1
2
4
5
3
6
1
2
4
5
3
6
“Arcshield”
feature hides visible switching arc
Lit (not momentary)
Lit (not momentary)
Lit (not momentary)
Matt or gloss
Gloss only
Top view
(On Off only - not momentary)