Panasonic ALZ12B12 PCB Mount Relay ALZ12B12T Datenbogen

Produktcode
ALZ12B12T
Seite von 5
LZ (ALZ)
3
ds_61B15_en_lz: 170912D
2. Specifications
REFERENCE DATA
Characteristics
Item
Specifications
Contact
Arrangement
1 Form C, 1 Form A
Contact resistance (Initial)
Max. 100 m
(By voltage drop 6V DC 1A)
Contact material
AgSnO
2  
type
Rating
Nominal switching capacity (resistive load)
16A 250V AC
Max. switching power (resistive load)
4,000V A
Max. switching voltage
440V AC
Max. switching current
16A
Nominal operating power
400mW
Min. switching capacity
*1
*1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual 
load.
100mA 5V DC
Electrical 
characteristics
Insulation resistance (Initial)
Min. 1,000M
 (at 500V DC)
Breakdown voltage 
(Initial)
Between open contacts
1,000 Vrms for 1min. (Detection current: 10mA)
Between contact and 
coil
5,000 Vrms for 1min. (Detection current: 10mA)
Temperature rise (at 20
C 
68
F
)
Max. 55
C 
131
F
[with nominal coil voltage and at 16A contact carrying current (resistance method) at 20°C 
68
F
]
Surge breakdown voltage
*2
(Between contacts and coil)
*2 Wave is standard shock voltage of 
1.2  50s according to JEC-212-1981
10,000 V (Initial)
Operate time (at nominal voltage) (at 20
C 
68
F
)
Max. 15ms (excluding contact bounce time)
Release time (at nominal voltage) (at 20
C 
68
F
)
Max. 5ms (excluding contact bounce time, without diode)
Mechanical 
characteristics
Shock resistance
Functional
Min. 100 m/s
2
  {10G} (Half-wave pulse of sine wave: 11ms; detection time: 10
s.)
Destructive
Min. 1,000 m/s
2
 {100G} (Half-wave pulse of sine wave: 6ms.)
Vibration resistance
Functional
10 to 55 Hz at double amplitude of 1.5mm (Detection time: 10
s.)
(Only the N.C. side of 1 Form C is 0.8mm)
Destructive
10 to 55 Hz at double amplitude of 1.5mm
Expected life
Mechanical (at 180 cpm)
Min. 10
7
Electrical (at 20 cpm)
*3
*3 In order to obtain the full rated life cycles, the relay should be properly vented by removing the vent nib. For details, please refer to NOTES. 
N.O.: Min. 10
5
, N.C.: Min. 5
10
4
Conditions
Conditions for operation, transport and storage
*4
*5
*4 Class F type is ambient temperature 105°C 
+221
F
.
*5 The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport 
.
*
Please note that some of the specifications listed above may not comply with overseas standards.
Ambient temperature: –40
C to +85C 
–40
F to +185F
 (Class B)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed
20 cpm (at nominal switching capacity)
Unit weight
Approx. 12 g 
.42 oz
1. Max. switching power (AC resistive load)
2. Max. switching power (DC resistive load)
3. Coil temperature rise
Sample: ALZ11F12, 5pcs.
Measured portion: coil inside
Contact current: 0 A, 16 A
10
1
30
1000
1
10
16
100
100
440
Contact voltage, V
Contact current, A
10
0
1
10
100
100
Contact current, A
Contact voltage, V
100
0
120 125
110 115
105
130 135
30
25
35
40
50
45
55
20
Normal
temperature
Normal
temperature
16A
0A
85
°C
105
°C
85
°C
105
°C
Temperature rise, 
°C
Coil applied voltage, %V