ds_61B05_en_js: 080413D
RATING
1. Coil data
Note: * When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1
C
33.8
F
with
20
C
68
F
as a reference) and use a coil impressed voltage that is within the maximum applied voltage range.
2. Specifications
Notes:
*1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
*1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
*3. When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1
C
33.8
F
with 20
C
68
F
as a reference) and use a coil impressed voltage that is within the maximum applied voltage range.
Nominal coil
voltage
Pick-up voltage
(at 20
C
68
F
)
Drop-out voltage
(at 20
C
68
F
)
Nominal operating
current
[
10%] (at 20C
68
F
)
Coil resistance
[
10%] (at 20C
68
F
)
Nominal operating
power
(at 20
C
68
F
)
Max. applied voltage
(at 70
C
158
F
)
5V DC
70%V or less of
nominal voltage
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
72 mA
69.4
360mW
130%V of
nominal voltage
[When using relays at
85
C
185
F
, see Note*]
6V DC
60 mA
100
9V DC
40 mA
225
12V DC
30 mA
400
18V DC
20 mA
900
24V DC
15 mA
1,600
48V DC
7.5mA
6,400
Characteristics
Item
Specifications
Contact
Contact material
AgSnO
2
type
Contact resistance (Initial)
Max. 100 m
(By voltage drop 6 V DC 1A)
Arrangement
1 Form A, 1 Form C
1 Form A Long endurance type
Rating
Nominal switching capacity (resistive load)
10 A 250 V AC (NO), 10 A 125 V AC,
6 A 277 V AC, 5 A 30 V DC
10 A 250 V AC, 10 A 277 V AC, 5 A 30 V DC
Max. switching power (resistive load)
2,500VA 150W (NO), 1,662VA 150W (NC)
2,770VA 150W
Max. switching voltage
250V AC, 100V DC (0.5A)
Max. switching current
10A (AC), 5A (DC)
Nominal operating power
360mW
Min. switching capacity*
1
100mA, 5V DC
Electrical
characteristics
characteristics
Insulation resistance (Initial)
Min. 100M
(at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
(Initial)
Between open contacts
750 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil
1,500 Vrms for 1 min. (Detection current: 10 mA)
Temperature rise (coil)
Max. 35
C
95
F
(By resistive method, nominal coil voltage applied to the coil;
contact carrying current: 10A, at 70
contact carrying current: 10A, at 70
C
158
F
)
Operate time (at nominal voltage) (at 20
C
68
F
)
Max. 10 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20
C
68
F
)
Max. 10 ms (excluding contact bounce time) (Without diode)
Mechanical
characteristics
characteristics
Shock resistance
Functional
98 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10
s.)
Destructive
980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional
10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10
s.)
Destructive
10 to 55 Hz at double amplitude of 2 mm
Expected life
Mechanical (at 180 times/min.)
Min. 10
7
Electrical (resistive load)
1
10
5
[10A 125V AC, 6A 277V AC, 5A 30V DC]
5
10
4
(NO contact only)
[10A 250V AC]
2
10
5
[10A 277V AC]
1.5
10
5
[10A 250V AC (at 20 times/min., 105
C
221
F
)]
1
10
5
[5A 30V DC]
Conditions
Conditions for operation, transport and storage*
2
–40
C to +70C
–40
F to +158F
(Class E insulation)
–40
C to +85C
–40
F to +185F
(Class B insulation)*
3
–40
C to +105C
–40
F to +221F
(Class F insulation)*
3
Humidity: 5 to 85% R.H. (Not freezing and
condensing at low temperature)
–40
C to +105C
–40
F to +221F
*
3
;
Humidity: 5 to 85% R.H. (Not freezing and
condensing at low temperature)
Max. operating speed
20 times/min. (at nominal switching capacity)
Unit weight
Approx. 12 g