Panasonic JQ1AP-B-12V-F PCB Mount Relay JQ1APB12FT Datenbogen
Produktcode
JQ1APB12FT
JQ
3
ds_61B03_en_jq: 201112D
3. Expected electrical life
REFERENCE DATA
Standard type
Type
Switching capacity
No. of operations
Standard type
1 Form A
5 A 125 V AC
3 A 125 V AC
2 A 250 V AC
3 A 125 V AC
2 A 250 V AC
5 A 30 V DC
5
10
4
2
10
5
2
10
5
10
5
1 Form C
N.O.
5 A 125 V AC
3 A 125 V AC
2 A 250 V AC
3 A 125 V AC
2 A 250 V AC
3 A 30 V DC
5
10
4
2
10
5
2
10
5
10
5
N.C.
2 A 125 V AC
1 A 250 V AC
1 A 30 V DC
2
10
5
2
10
5
10
5
High capacity type
1 Form A
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
5
10
4
5
10
4
10
5
1 Form C
N.O.
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
5
10
4
5
10
4
10
5
N.C.
3 A 125 V AC
2 A 250 V AC
1 A 30 V DC
2
10
5
2
10
5
10
5
1.-(1) Max. switching capacity (1 Form A type)
1.-(2) Max. switching capacity (1 Form C type)
AC resistive load (High capacity type)
AC resistive load (Standard type)
1
10
100 250
1,000
10
100
5
Contact voltage, V
Contact current, A
1
10
100 250
1,000
10
100
2
3
5
Contact voltage, V
Contact current, A
AC resistive load
(High capacity type) N.O. side
(High capacity type) N.O. side
AC resistive load
(High capacity type)
N.C. side
(High capacity type)
N.C. side
AC resistive load
(Standard type) N.O. side
(Standard type) N.O. side
AC resistive load
(Standard type)
N.C. side
(Standard type)
N.C. side
2. Life curve
Ambient temperature: room temperature
3.-(1) Operate & release time (1 Form A type)
Tested sample: JQ1a-12V-F, 25 pcs.
3.-(2) Operate & release time (1 Form C type)
Tested sample: JQ1-24V-F, 25 pcs.
100
10
1
1
0
2
3
4
5
Contact current, A
Life,
×
10
4
125V AC
resistive load
resistive load
250V AC
resistive load
resistive load
80
100
120
150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Max.
Max.
Min.
Min.
Min.
Min.
80
100
120
150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Min.
Min.
Min.
Max.
Max.