Crydom SPF240D25 Solid State SIP PCB Load Relay SPF240D25 Datenbogen

Produktcode
SPF240D25
Seite von 4
INPUT SPECIFICATIONS (1)
Description
SPF240D25
SPF380D/480D
SPFExxxD25
SPF240A25
SPFE240A25
Control Voltage Range 
3-15 VDC
4-15 VDC
15-32 VDC
90-140 VAC
18-36 VAC
Maximum Turn On Voltage
3.0 VDC
4.0 VDC
15.0 VDC
90.0 Vrms
18.0 Vrms
Minimum Turn-Off Voltage
1.0 VDC
1.0 VDC
1.0 VDC
10.0 Vrms
2.0 Vrms
Typical Input Current @ Nominal Voltage
15 mAdc
15 mAdc
15 mAdc
10 mAdc
10 mAdc
Nominal Input Impedance 
300 Ohm
240 Ohm
1500 Ohm
14.1 k Ohm
2.1 k Ohm
Maximum Turn-On Time [msec] (4)
1/2 Cycle
1/2 Cycle
1/2 Cycle
10
10
Maximum Turn-Off Time [msec] 
1/2 Cycle
1/2 Cycle
1/2 Cycle
40
40
GENERAL SPECIFICATIONS
Description
Parameters
Dielectric Strength, Input/Output/Base (50/60Hz)
4000 Vrms
Minimum Insulation Resistance (@ 500 VDC)
10 
9
 Ohm
Maximum Capacitance, Input/Output
8 pF
Ambient Operating Temperature Range
-30 to 80˚C
Ambient Storage Temperature Range
-30 to 125˚C
Weight (typical)
0.85 oz. (25g)
Encapsulation
Thermally Conductive Epoxy
 
GENERAL NOTES 
1) All parameters at 25°C unless otherwise specified. 
2) Off-State dv/dt test method per EIA/NARM standard RS-443,13.11.1 
3) Heatsink  temperature 85  ûC  Maximum.   
4) Turn-On Time for Random Turn-On versions 0.1 msec (DC Control Models)
MECHANICAL SPECIFICATIONS
 
 AC CONTROL  
 PIN 1: AC LOAD 
 PIN 2: AC LOAD 
 PIN 3: AC CONTROL 
 PIN 4: AC CONTROL 
 
 
 DC CONTROL  
 PIN 1: AC LOAD 
 PIN 2: AC LOAD 
 PIN 3: +DC CONTROL 
  PIN  4:  -DC C ON TR OL 
 
 
 
UL E116950 
                                                                                                                       Rev. 061608 
THERMAL DERATE INFORMATION
For Contact information visit our web  
site. 
      www.crydom.com 
©2008 Crydom, Inc.
Specifications  subject to change without notice.