Crydom Solid State Relay El100D10-24 EL100D10-24 Datenbogen

Produktcode
EL100D10-24
Seite von 5
EL Series
 
• Ratings of 5A and 10A @ 3-100 VDC  
• UL Recognized, CE and RoHS Compliant  
• 5, 12 and 24VDC control  
• Mosfet Output 
 
PRODUCT SELECTION
Control Voltage
5A
10A
4-8 VDC 
EL100D5-05
EL100D10-05
10-14 VDC 
EL100D5-12
EL100D10-12
21-27 VDC 
EL100D5-24
EL100D10-24
OUTPUT SPECIFICATIONS (1)(3)
Description
5A
10A
Operating Voltage Range [VDC]
3-100
3-100
  
Maximum Load Current  [Adc] (2)
5
10
  
Minimum Load Current [mAdc]
150
150
Transient Overvoltage [Vpk]
600
600
Maximum Surge Current Non-Repetitive (10ms) [A]
115/120
145/150
Maximum I² t for Fusing (50/60Hz, 1/2 cycle) [A² sec]
65/60
100/95
Maximum Off-State Leakage Current @ Rated Voltage [µAdc]
100
100
Maximum On-State Resistance @ Rated Current (Rds-on)
0.04 Ohm
0.01 Ohm
Maximum On-State Voltage Drop @ Rated Current
0.2V
0.1V
INPUT SPECIFICATIONS (1)
Description
EL100Dxx-05
EL100Dxx-12
EL100Dxx-24
Control Voltage Range 
4-8 VDC
10-14 VDC
21-27 VDC
Minimum Turn-On Voltage 
4.0 VDC
10 VDC
21 VDC
Minimum Turn-Off Voltage
0.5 VDC
1.0 VDC
2 VDC
Typical Input Current @ nominal turn-on voltage
13.3 mA
11.7 mA
11.5 mA
Nominal Input Impedance [Ohms]
300
940
2K
Maximum Turn-On Time  [msec] 
1
1
1
Maximum Turn-Off Time  [µsec] 
300
300
300
GENERAL SPECIFICATIONS
Description
Parameters
Dielectric Strength, Input to Output 
2500 Vrms
  
  
Dielectric Strength, Output to Baseplate 
2500 Vrms
Ambient Operating Temperature Range
-30 to 80 °C
Ambient Storage Temperature Range
-30 to 125 °C
Weight (typical)
0.5 oz (14.4g)
Terminals
3/16" input, 1/4" output QC
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified. 
2) When mounted to the proper size heat sink (see derating curves) 
3) Inductive loads should be diode suppressed to prevent damage to the relay.