Crydom CKRD2420 DIN Rail Solid State Contactor CKRD2420 Datenbogen

Produktcode
CKRD2420
Seite von 5
INPUT SPECIFICATIONS (1)
Description
CKRD24xx
CKRA24xx
CKRA24xxE
Control Voltage Range 
4.0-32 VDC
90-280 Vrms
18-36 Vrms
Maximum Turn-On Voltage
4.0 VDC
90 Vrms
18 Vrms
Minimum Turn-Off  Voltage
1.0 VDC
10 Vrms
4.0 Vrms
Typical Input Current  (4)
8-12 mA
2 mA @ 120 Vrms, 4 mA @ 240 Vrms
10 mA @ 240 Vrms
Maximum Turn-On Time  [msec] (3)
1/2 Cycle
10
10
Maximum Turn-Off Time  [msec] 
1/2 Cycle
40
40
GENERAL SPECIFICATIONS
Description
Parameters
Dielectric Strength, Input/Output/Base (50/60Hz)
4000Vrms
Minimum Insulation Resistance (@ 500 V DC)
10
9
 Ohms
Maximum Capacitance, Input/Output
8 pF
Ambient Operating Temperature Range
-40ºC to 80ºC
Ambient Storage Temperature Range
-40ºC to 125ºC
Status Indicator Display
Green LED
Weight (typical)
10 oz. (280g)
Encapsulation
Thermally Conductive Epoxy
Terminals
Box Clamp Type
Maximum Wire Size:
AWG # 10 (3mm)
Recommended Terminal Screw Torque Range:
5.0-6.0 in lb (0.6-0.7 Nm)
Min. Side by Side Spacing
0.8 inch (20mm)
 
GENERAL NOTES 
1) All parameters at 25°C unless otherwise specified. 
2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1  
3) Turn-on time for DC control random turn-on versions is 0.02 msec  
4) Input circuitry for DC control version incorporates active current limiter.