INPUT SPECIFICATIONS (1)
Description
 EZ240D5
 EZ240Dxx
 EZ480Dxx
 EZExxxDxx
EZxxxAxx
EZExxxAxx
Control Voltage Range 
3-15 VDC
3-15 VDC
4-15 VDC
15-32 VDC
90-140 Vrms
18-36 Vrms
Minimum Turn-On Voltage 
3.0 VDC
3.0 VDC
4.0 VDC
15.0 VDC
90.0 Vrms
18.0 Vrms
Minimum Turn-Off Voltage 
1.0 VDC
1.0 VDC
1.0 VDC
1.0 VDC
10.0 Vrms
2.0 Vrms
Typical Input Current @ Nominal Voltage
15 mAdc
15 mAdc
15 mAdc
15 mAdc
10 mA
10 mA
Nominal Input Impedance 
300 Ohm
300 Ohm
240 Ohm
1500 Ohm
10.6 k Ohm
1.8 k Ohm
Maximum Turn-On Time  [msec] (6)
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
10
10
Maximum Turn-Off Time  [msec] 
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
40
40
GENERAL SPECIFICATIONS
Description
Parameters
Dielectric Strength, Input/Output/Base (50/60Hz)(3)
4000 Vrms *
Minimum Insulation Resistance (@ 500 V DC)
10
9
 Ohm
  
  
  
Maximum Capacitance, Input/Output
8 pF
Ambient Operating Temperature Range
-40 to 80 °C
Ambient Storage Temperature Range
-40 to 125 °C
Weight (typical)
1.5 oz (43 g)
Encapsulation
Thermally conductive Epoxy
Terminals
0.25 Inch Faston
Mounting Screw Torque (8-32 UNC screw) [in lbs/Nm]
8-14/1.1-1.5
GENERAL NOTES
 
1) All parameters at 25°C unless otherwise specified. 
2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 
3) 240V, DC control models only, all others 2500VRMS 
4) Heat sinking required, see derating curves. 
5) Off- state leakage for snubbered version (suffix S, 240V version only) is 10.0mArms  
6) Turn-on time for random turn-on versions is 0.1 msec (DC Control Models). 
240V, DC control models only 