Sharp S 216 S02 Electronic Load Relay S 216 S02 Datenbogen
Produktcode
S 216 S02
S112S01 Series/S116S01 Series
Ambient temperature T
a
(˚C)
- 25
0
25
50
75
100
125
0
2
4
6
8
10
12
(1)
(2)
(3)
(4)
(5)
Ambient temperature T
a
(˚C)
- 25
0
25
50
75
100
125
0
2
4
6
8
10
12
14
16
18
(1)
(2)
(3)
(4)
(5)
Fig. 1 RMS ON-state Current vs. Ambient
Fig. 2 RMS ON-state Current vs. Ambient
125
Ambient temperature T
a
(˚C)
Forward current I
F
(
mA
)
25
- 25
0
0
75
50
100
50
10
20
30
40
60
Case temperature T (˚C)
- 25
0
25
50
75
100
125
0
2
4
6
8
10
12
14
16
S116S01Series
S112S01Series
Fig. 3 RMS ON-state Current vs.
Case Temperature
Fig. 4 Forward Current vs.
Ambient Temperature
Temperature
Temperature
RMS On-state current I
T
RMS ON-state current I
T
(
Arms
)
( S112S01Series)
( S116S01Series)
RMS On-state current I
T
(
Arms
)
( Note) With the Al heat sink set up vertically,tighten the device at the center of the Al heat sink with a torque
shall not be carried out.
c
(
Arms
)
of 0.4N • m and apply thermal conductive silicone grease on the heat sink mounting plate. Forcible cooling
( 1) With infinite heat sink
( 2) With heat sink ( 280 x 280 x 2 mm Al plate )
( 3) With heat sink ( 200 x 200 x 2 mm Al plate )
( 4) With heat sink ( 100 x 100 x 2 mm Al plate )
( 5) Without heat sink
( 2) With heat sink ( 280 x 280 x 2 mm Al plate )
( 3) With heat sink ( 200 x 200 x 2 mm Al plate )
( 4) With heat sink ( 100 x 100 x 2 mm Al plate )
( 5) Without heat sink
( 1) With infinite heat sink
( 2) With heat sink ( 280 x 280 x 2 mm Al plate)
( 3) With heat sink ( 200 x 200 x 2 mm Al plate)
( 4) With heat sink ( 100 x 100 x 2 mm Al plate)
( 5) Without heat sink
( 2) With heat sink ( 280 x 280 x 2 mm Al plate)
( 3) With heat sink ( 200 x 200 x 2 mm Al plate)
( 4) With heat sink ( 100 x 100 x 2 mm Al plate)
( 5) Without heat sink