Crydom D2W203F-11 Solid State SIP PCB Load Relay D2W203F-11 Datenbogen

Produktcode
D2W203F-11
Seite von 4
D2W Series
 
 
• SIP SSR 
• Ratings to 3.5A @ 280 VAC  
• DC control  
• Zero-crossing (resistive loads) output  
• Internal snubber network 
PRODUCT SELECTION
Control Voltage
2A
3A
3.5A
3-32 VDC
D2W202F
D2W203F
D2W203F-11
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms]
24-280
24-280
24-280
Transient Overvoltage [Vpk]
600
600
600
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
8
8
8
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3)
200
200
200
Maximum Load Current [Arms]
2
3
3.5
Minimum Load Current [Arms]
0.06
0.06
0.06
Maximum Surge Current (16.6ms) [Apk]
28
70
80
Maximum On-State Voltage Drop @ Rated Current [Vpk]
1.4
1.4
1.4
Minimum Power Factor (with Maximum Load)
0.5
0.5
0.5
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range 
3-32 VDC
Must Turn On Voltage
3.0 VDC
Must Turn Off Voltage
1.0 VDC
Typical Input Current @ 5 VDC
3.0 mAdc
Nominal Input Impedance 
1500 Ohm
Maximum Turn-On Time [msec] 
1/2 Cycle
Maximum Turn-Off Time [msec] 
1/2 Cycle
GENERAL SPECIFICATIONS
Description
Parameters
Dielectric Strength, Input/Output/Base (50/60Hz)(2)
4000 Vrms
Minimum Insulation Resistance (@ 500 VDC)(2)
10 
9
 Ohm
Maximum Capacitance, Input/Output
10 pF
Ambient Operating Temperature Range
-30 to 80°C
Ambient Storage Temperature Range
-30 to 125°C
Weight (typical)
0.6 oz. (17g)
Encapsulation
Thermally Conductive Epoxy
 
GENERAL NOTES 
1) All parameters at 25°C unless otherwise specified. 
2) Dielectric and insulation resistance are measured between input and output 
3) Off-State dv/dt test method per EIA/NARM standard RS 
For Contact information visit our web  
site. 
      www.crydom.com 
©2008 Crydom, Inc.
Specifications  subject to change without notice.