Merten Insert Main panel insert System M, System Area, Aquadesign MEG5190-0000 MEG5190-0000 Benutzerhandbuch
![Merten](https://files.manualsbrain.com/attachments/174c591b5cff3795971b2358ef882811b496f4c0/common/fit/150/50/9779dce0cc3b30ed4368a2f84783f9287c846094d4ac618f6bfb6976e363/brand_logo.gif)
Produktcode
MEG5190-0000
V5190-581-00 12/11
Global blind control
Example of raising/lowering and up/down in steps
of up to 4 PL lines
When the display timer module on the central unit insert
When the display timer module on the central unit insert
is pressed, all loads in the PL lines are controlled togeth-
er:
• Long press on the push-button (> 0.5 s): raising/lower-
• Long press on the push-button (> 0.5 s): raising/lower-
ing
• Short press on the push-button (< 0.5 s): up/down in
steps
A Display timer module on central unit insert
B Blind control insert
B Blind control insert
(Only with push-button module, 2-gang)
|
When you save a scene, please always save the
current state of all connected devices in all con-
nected PL lines.
Proceed as follows to change and save a scene accord-
ing to your requirements:
1 Retrieve scene.
2 Change the states of individual devices in the light
1 Retrieve scene.
2 Change the states of individual devices in the light
and/or blind scene.
3 Check that all devices are in the state you require.
4 Save scene.
4 Save scene.
Operating the central unit: retrieving,
changing and saving global scenes via
PlusLink
A
B
B
B
PL4 PL3 PL2
PL1
< 0,5 s
>
> 0,5 s
< 0,5 s
> 0,5 s
Retrieving light or blind scenes
Standard scenes
All receiving devices are delivered from the factory with
All receiving devices are delivered from the factory with
presettings for a light or blind scene.
1 Retrieve scene: press the S1 or S2 push-button
briefly.
• The devices of the light scene adopt the saved bright-
ness value.
• The devices of the blind scene initially move to the up-
permost position. After a running time of maximum 2
minutes has elapsed, the blinds move to the saved po-
sition.
A Central unit insert
B Mechanical push-button (panic button)
C PL line with blind scene: Blind control insert
D PL line with light scene: e.g. electronic switch insert,
B Mechanical push-button (panic button)
C PL line with blind scene: Blind control insert
D PL line with light scene: e.g. electronic switch insert,
relay switch insert, universal dimmer insert, DALI in-
sert, or 1-10 V insert
E PL line with light scene: e.g. electronic switch insert,
relay switch insert, universal dimmer insert, DALI in-
sert, or 1-10 V insert
Changing and saving light scenes
Using the example of the universal dimmer insert as the
receiving device in the PL line
1 Retrieve scene: press the S1 or S2 push-button
briefly.
2 Set the brightness values of the lamps that you want
to change on the receiving device.
3 Save scene: press the S1 or S2 push-button for a
long time.
All lamps are switched off briefly and then back on again
to indicate that the saving procedure has been success-
ful. Then the lamps adopt the saved brightness value.
S1:
light on (100 %) / blind up
S2:
light off / blind down
Panic button: light on (100 %) / blind down
A
PL4
max. 10
C
PL3
max. 10
D
PL2
max. 10
E
PL1
B
< 0,5 s
> 3 s
2
3
1
Changing and saving blind scenes
In combination with the push-button module Basic on the
receiving insert, you can only save the fixed position val-
ues of "up/down" (2A) for blind scenes.
In combination with the push-button modules Comfort or
Comfort Plus on the receiving insert, you can save any
position values (2B).
The blinds move down a step and then back up to indi-
cate that the saving procedure has been successful.
Retrieving panic scenes
Standard scenes
All devices are delivered from the factory with preset-
All devices are delivered from the factory with preset-
tings for a panic scene.
1 Retrieve panic scene: press the panic button briefly.
A Central unit insert
B Mechanical push-button (panic button)
C PL line with panic scene: e.g. electronic switch in-
B Mechanical push-button (panic button)
C PL line with panic scene: e.g. electronic switch in-
sert, relay switch insert, universal dimmer insert,
DALI insert, or 1-10 V insert
D PL line with panic scene: Blind control insert
1 Retrieve scene: press the S1 or S2 push-button
briefly.
2 A Set the positions (up/down) of the blinds that
you want to change on the receiving device.
B Set the positions (any values) of the blinds that
you want to change on the receiving device.
3 Save scene: press the S1 or S2 push-button for a
long time.
Panic button: Light on (100 %) / blind down / switch-
ing duration = 30 minutes
< 0,5 s
>
> 3 s
2
3
1
A
A
B
A
C
C
D
D
B
PL3
PL2
PL4
PL1
30 min
Changing and saving panic scenes
In the case of panic scenes, you can only save start and
end values such as "on/off" for the lightscene or "up/
down" for the blind scene.
1 Retrieve panic scene: short press on the mechani-
cal push-button (panic button).
2 Set the positions (up/down) of the blinds that you
want to change on the receiving device.
3 Set the brightness values (on/off) of the lamps that
you want to change on the receiving device.
4 Save the panic scene: long press on the mechanical
push-button (panic button).
The blinds move down a step and then back up to indi-
cate that the saving procedure has been successful. The
lamps are switched off briefly and then back on again,
and then return to their saved brightness value.
|
The panic scene has the same priority as the glo-
bal scenes of the central unit insert.
Merten GmbH, Fritz-Kotz-Str. 8, D-51674 Wiehl
www.merten.com
Service Center:
www.merten.com
Service Center:
Technical support / InfoLine:
Technical data
Nominal voltage:
AC 220/230 V ∼, 50/60 Hz
Neutral conductor:
required
Output:
4 x PlusLink
Connecting terminals: Screw terminals for max. 2x
2.5 mm
2
or 2x 1.5 mm
2
Protection:
max. 16 A circuit breaker
Merten GmbH
Phone: +49 2261 702-204
Fax:
Fax:
+49 2261 702-136
E-Mail: servicecenter@merten.de
Phone: +49 2261 702-235
Fax:
Fax:
+49 2261 702-680
E-Mail: infoline.merten@schneider-electric.com
> 3 s
< 0,5 s
4
2
1
3