Gw Instek GDS-2304A 4-channel oscilloscope, Digital Storage oscilloscope, GDS-2304A Datenbogen

Produktcode
GDS-2304A
Seite von 220
 
 
COMMAND DETAILS 
69 
Parameter 
<X> 
1, 2 (Cursor 1, Cursor 2) 
Return parameter  <NR3>  Returns the ratio. 
Example 
:CURSor:XY:RATio:POSition? 
6.717E+1 
Returns the ratio value as 6.717V/V. 
:CURSor:XY:RATio:DELta 
Query
 
 
Description 
Queries the ratio delta in XY mode.  
Syntax 
:CURSor:XY:RATio:DELta {?} 
Return parameter  <NR3>  Returns the ratio delta. 
Example 
:CURSor:XY:RATio:DELta? 
5.39E+1 
Returns the ratio delta as 53.9V/V. 
Display Commands 
 
 
:DISPlay:INTensity:WAVEform ................................... 69
 
:DISPlay:INTensity:GRATicule.................................... 70
 
:DISPlay:PERSistence ................................................. 70
 
:DISPlay:GRATicule .................................................... 70
 
:DISPlay:WAVEform .................................................... 72
 
 
 
:DISPlay:INTensity:WAVEform  
Set
Query
 
 
Description 
Sets or queries the waveform intensity level.   
Syntax 
:DISPlay:INTensity:WAVEform {<NRf> | ?} 
Parameter 
<NRf> 
0.0E+0 to 1.0E+2 (0% to 100%) 
Return Parameter  <NR3>  Returns the display intensity. 
Example 
:DISPlay:INTensity:WAVEform 5.0E+1 
Sets the waveform intensity to 50%.