Gw Instek USG-3044 Function Generator, Frequency Generator USG-3044 Datenbogen
Produktcode
USG-3044
USG Series User Manual
46
Spurious related to
Resolution settings
(Single Point Mode)
Resolution settings
(Single Point Mode)
≤ -30 dBc, typical
Resolution < 1MHz
≤ -65 dBc, typical
Resolution ≥ 1MHz
Spurious related to the
fundamental output
(Single Point Mode)
fundamental output
(Single Point Mode)
≤ -65 dBc, typical
*: Minimum step depands on the computer being used. This min. step will be
automatically adjusted by the PC software. 1ms is achieved on a faster system.
automatically adjusted by the PC software. 1ms is achieved on a faster system.
Common Specifications
Software for PC:
a. Primary RF supports operating system: Windows 2000/XP/Vista/7/8
b. Java USG Control Panel: Windows 2000/XP/Vista/7/8 Linux/OS X
Software for mobile device:
For Android 4.0 and higher with OTG*
Interface
USB 2.0
USB Connector Type
Mini-B
Supply Voltage
5V
nominal
RF Connector Type
N-type male
Impedance
50 ohm
nominal
Output VSWR
< 1.5:1
Output level @ -30dBm
Max. DC voltage
connected to output
connected to output
+/-25VDC
Max. Reverse Power
+30dBm
*Warning: Some Android devices with OTG support cannot run the USG app due
to the OTG driver modifications by vendors.
to the OTG driver modifications by vendors.