Wachendorff LD4A05P0 Current-/voltage display LD4A05P0 LD4A05P0 Datenbogen

Produktcode
LD4A05P0
Seite von 16
1
AIR PRESSURE STABILIZATION VENT
(57.15)
2.25
X
Z
Y
GENERAL DESCRIPTION
The Large Display is a versatile display available as a DC volt, current, or 
process meter with scaling, serial communications and dual relay outputs. The 5  
digit displays are available in either 2.25" or 4" high red LED digits with 
adjustable display intensities. The 2.25" high models are readable up to 130 feet. 
The 4" high models are readable up to 180 feet. Both versions are constructed 
of a NEMA 4X/IP65 enclosure in light weight aluminum.
All models also come with dual  Form C relay outputs and RS232 / RS485 
serial communications.
SAFETY SUMMARY
All safety regulations, local codes and instructions that appear in this and 
corresponding literature, or on equipment, must be observed to ensure personal 
safety and to prevent damage to either the instrument or equipment connected to 
it. If equipment is used in a manner not specified by the manufacturer, the 
protection provided by the equipment may be impaired.
ORDERING INFORMATION
MODEL NO.
DESCRIPTION
PART NUMBER
LD2A
2.25" High 5 Digit Red LED Volt/Current Meter w/ 
Relay Output and RS232/RS485 Serial Comms
LD2A05P0
LD4A
4" High 5 Digit Red LED Volt/Current Meter w/ 
Relay Output and RS232/RS485 Serial Comms
LD4A05P0
LD Plug
Panel Meter Plug for LD models 
  (NOT included in LD Product UL File)
LDPLUG00
SPECIFICATIONS
1. DISPLAY: 5 digit, 2.25" (57 mm) or 4" (101 mm) intensity adjustable Red LED 
(-99999 to 99999)
2. POWER REQUIREMENTS:
AC POWER: 50 to 250 VAC 50/60 Hz, 26 VA
DC POWER: 21.6 to 250 VDC, 11 W
DC Out: +24 VDC @ 100 mA if input voltage is greater than 50 VAC/VDC 
+24 VDC @ 50 mA if input voltage is less than 50 VDC
Isolation: 2300 Vrms for 1 min. to all inputs and outputs
3. INPUT RANGES: Jumper Selectable
D.C. Voltages: 200 mV, 2 V, 20 V, 200 V, 10 V
D.C. Currents: 200 
A, 2 mA, 20 mA, 200 mA
D.C. Process: 4 to 20 mA, 1 to 5 VDC, 0/1 to 10 VDC
4. OVERRANGE/UNDERRANGE INDICATION:
Input Overrange Indication:  “
OLOL
”.
Input Underrange Indication:  “
ULUL
”.
Display Overrange/Underrange Indication: “
.....
”/“-
.....
” 
  2.25" & 4" HIGH RED LED DIGITS
  PROGRAMMABLE SCALING AND DECIMAL POINTS
  PROGRAMMABLE USER INPUT
  DUAL 5 AMP FORM C RELAY
  ALUMINUM NEMA 4X/IP65 CASE CONSTRUCTION
  RS232/RS485 SERIAL COMMUNICATIONS
  UNIVERSALLY POWERED
MODEL LD - LARGE DC VOLT/CURRENT/PROCESS DISPLAY
DIMENSIONS  In inches (mm)
Bulletin No.  LDA-C
Drawing No.  LP0673
Released  09/09
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
CAUTION: Risk of Danger.
Read complete instructions prior to 
installation and operation of the unit.
CAUTION: 
Risk of electric shock.
INPUT 
RANGE
INPUT 
IMPEDANCE
MAX 
INPUT 
SIGNAL
RESOLUTION
TEMP. 
COEFFICIENT
200 mV
0.1% of span
1.027 M
75 VDC
10 μV
70 ppm /°C
2 V
0.1% of span
1.027 M
75 VDC
0.1 mV
70 ppm /°C
20 V
0.1% of span
1.027 M
250 VDC
1 mV
70 ppm /°C
10 V
200 V
0.1% of span
0.1% of span
538 K
1.027 M
30 V
250 VDC
1 mV
10 mV
70 ppm /°C
70 ppm /°C
ACCURACY @ 
23 
C LESS 
THAN 85% RH
INPUT 
RANGE
INPUT 
IMPEDANCE
MAX 
INPUT 
SIGNAL
RESOLUTION
TEMP. 
COEFFICIENT
200 μΑ
0.1% of span
1.111 K
15 mA
10 nA
70 ppm /°C
2 mA
0.1% of span
111 
50 mA
0.1 μA
70 ppm /°C
20 mA
0.1% of span
11 
150 mA
1 μA
70 ppm /°C
200 mA
0.1% of span
500 mA
10 μA
70 ppm /°C
ACCURACY @ 
23 
C LESS 
THAN 85% RH
22 (558.8)
12 (304.3)
Z (Center)
7.875 (200)
26 (660.4)
LD4A05P0
4 (101.6)
16 (406.4)
LD2A05P0
Y (Height)
X (Length)
PART 
NUMBER
The protective conductor terminal is bonded to conductive 
parts of the equipment for safety purposes and must be 
connected to an external protective earthing system.
INPUT RANGE
SELECT RANGE
4 - 20 mA
Use the 20 mA range
1 - 5 VDC
Use the 10V range
1 - 10 VDC
Use the 10V range
CC
US LISTED
US LISTED
UL
R
51EB
IND. CONT. EQ.
CC
US LISTED
US LISTED
UL
R
LABORATORY EQUIPMENT
3RSD