REMOTE INTERFACE 
109 
SOURce[1]:VOLTage:UNIT 
Set
Query
 
 
Description 
Sets or queries the output amplitude units. There 
are three types of units: VPP, VRMS and DBM. The 
SOURce[1]:VOLTage:UNIT command does not set 
the offset units. 
Note 
The units set with the VOLTage:UNIT command 
will be used as the default unit for all amplitude 
units unless a different unit is specifically used for 
a command, such as those used with the Apply 
commands.  
Syntax 
SOURce[1]:VOLTage:UNIT {VPP|VRMS|DBM}
 
Example 
SOUR1:VOLT:UNIT VPP 
 
Sets the amplitude units to Vpp. 
Query Syntax 
SOURce[1]:VOLTage:UNIT?
 
Return Parameter  VPP 
Vpp 
 
VRMS 
Vrms 
 
DBM 
dBm 
Query Example 
SOUR1:VOLT:UNIT
>VPP
 
 
The amplitude units are set to Vpp.