Conrad Energy Camera rechargeable battery replaces original battery NP-BG1 3.7 V 700 mAh 251242 Datenbogen

Produktcode
251242
Seite von 6
Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau
Item no.: 251242
Material Safety Data Sheet
Page 2 of 6
3. Independent Certification of Lithium-Ion cell UN Transportation Model Regulation
No
Test Item
Criteria
Result
Remark
T1
Altitude Simulation
No mass loss,leakage,venting,disassembly,rupture,and fire.
OCV should not be less than 90% before testing.
Passed
T2
Thermal Test
No mass loss,leakage,venting,disassembly,rupture,and fire.
OCV should not be less than 90% before testing.
Passed
T3
Vibration
No mass loss,leakage,venting,disassembly,rupture,and fire.
OCV should not be less than 90% before testing.
Passed
T4
Shock
No mass loss,leakage,venting,disassembly,rupture,and fire.
OCV should not be less than 91% before testing.
Passed
T5
External Short
Circuit
External temperature should not exceed 170 degC.
No disassembly,rupture,and fire within six hours of this test.
Passed
T6
Impact
External temperature should not exceed 170 degC.
No disassembly,and fire within six hours of this test.
Passed
T7
Overcharge
No disassembly,and fire within seven days of this test.
Passed
Battery only
T8
Forced Discharge
No disassembly,and fire within seven days of this test.
Passed
We confirm the test results based on the UN manual of tests and criteria 383
4. Hazards Identification
All chemical materials of lithium ion battery cell are stored in a hermetically sealed metal case, designed to withstand
temperatures and pressures encountered during normal use. There is no physical danger of ignition or explosion and chemical
danger of hazardous materials' leakage during normal use. However, if exposed to a fire, added mechanical shocks,
decomposed, added electric stress by miss-use, the gas release vent will be operated and hazardous materials may be
released.
Potential Health Effects:
Cobalt and Cobalt compounds are considered to be possible human carcinogen(s). These chemicals may cause allergic skin
sensitization (rash) and irritate eyes, skin, nose, throat, respiratory system.
Since electrolyte is flammable liquid, it does not bring close to fire. It may cause moderate to severe eye irritation, dryness of
the skin. Breathing of its mist, vapor or fume may irritate nose, throat and lungs. Exposure of electrolyte material in the area
which contains water may generate hydrofluoric acid, which can cause immediate burns on skin, severe eye burn. The
ingestion of electrolyte can cause serious chemical burns of mouth, esophagus and gastrointestinal tract.