INSYS Modem 56k small INT 2.0/USB 1.0
82
June 06
S91* Transmit Level
The value for the transmit level of the modem is stored in the S91 registry. The
value can be set between 0 and 15. The connection can in some cases be improved
by decreasing the transmit level.
by decreasing the transmit level.
S91=0
Transmit level -1 dBm
S91=15
Transmit level -16 dBm
Note:
The range and the default value depend on the country settings
(AT+GCI).
(AT+GCI).
S95* Result code
Bit
Meaning
Bit 0
CONNECT message with line speed
Bit 1
CONNECT/ARQ message for error corrected connection
Bit 2
CARRIER messages enabled (messages 40 – 47)
Bit 3
PROTOCOL messages enabled (messages 70 - 80)
Bit 4
Reserved
Bit 5
COMPRESSION messages enabled (messages 66 - 69)
Bit 6
Reserved
Bit 7
Reserved