Texas Instruments DEM-OPA-SSOP-3B demonstration fixture DEM-OPA-SSOP-3B DEM-OPA-SSOP-3B Datenbogen

Produktcode
DEM-OPA-SSOP-3B
Seite von 6
www.ti.com
4
Board Layout
5
Measurement Tips
Board Layout
Op Amp with Standard SSOP-16 Pinout—These op amps have the pinout shown in
shows typical values used for these parts. To select component values for a specific op amp (especially
R
F
x), consult the respective data sheet.
Table 2. Op Amp with Standard SSOP-16 Pinout
(1)
SINGLE-
DUAL-SUPPLY DUAL-SUPPLY
SUPPLY
COMPONENT
(G = +2)
(G = –1)
(G = +1)
R
B
x
49.9
Ω
10
Ω
49.9
Ω
R
B2
x
0
Ω
53.6
Ω
Open
R
S1
x
0
Ω
Open
0
Ω
R
S2
x
Open
0
Ω
Open
R
F
x
800
Ω
800
Ω
1k
Ω
R
G
x
800
Ω
800
Ω
Open
R
OUT
x
49.9
Ω
49.9
Ω
49.9
Ω
C
BYP
V
SP
2.2
µ
F
2.2
µ
F
2.2
µ
F
C
BYP
V
SN
2.2
µ
F
2.2
µ
F
Open
C
N
0.1
µ
F
0.1
µ
F
0
Ω
C
P
0.1
µ
F
0.1
µ
F
0.1
µ
F
C
PN
0.1
µ
F
0.1
µ
F
Open
L
P
0
Ω
0
Ω
0
Ω
L
N
0
Ω
0
Ω
Open
(1)
The values and gains listed here will not work for all op amps. See
the specific data sheet to select proper values. The I/O impedances
are 50
Ω
.
This demonstration fixture is a two-layer PCB. (See
.) It uses a ground plane on the bottom, and
signal and power traces on the top. The ground plane has been opened up around op amp pins sensitive
to capacitive loading. Power-supply traces are laid out to keep current loop areas to a minimum. The SMA
(or SMB) connectors may be mounted either vertically or horizontally.
The location and type of capacitors used for power-supply bypassing are crucial to high-frequency
amplifiers. The tantalum capacitors, C
BYP
V
SP
and C
BYP
V
SN
, do not need to be as close to pins 11 and 4 on
the PCB, and may be shared with other amplifiers.
See the individual op amp data sheet for more information on proper board layout techniques and
component selection.
This demonstration fixture, with the component values shown, is designed to operate in a 50
Ω
environment; most data sheet plots are obtained under these conditions. It is easy to change the
component values for different input and output impedance levels. However, do not use high-impedance
probes; they represent a heavy capacitive load to the op amp, and will alter the amplifier response.
Instead, use low-impedance (
500
Ω
) probes with adequate bandwidth. The probe input capacitance and
resistance set an upper limit on the measurement bandwidth. If a high-impedance probe must be used,
place a 100
Ω
resistor on the probe tip to isolate its capacitance from the circuit.
SBOU019A – April 2003 – Revised June 2006
DEM-OPA-SSOP-3B Demonstration Fixture
3