Texas Instruments BQ24380 Li+ Charger Front End Protection IC Evaluation Module BQ24380EVM BQ24380EVM Datenbogen

Produktcode
BQ24380EVM
Seite von 14
V
Power
Supply #1
Load
#2
V
I
Ibat
JMP8
U1
U2
APPLICATION CIRCUIT
JMP1 JMP2 JMP3 JMP4 JMP5 JMP6 JMP7
J4
BAT+
BAT -
DC+
DC-
F
AUL
T
BA
T+
OUT
DC
-
J3
J2
J1
HPA245 BQ2430x/1x/8x DSG EVM
DC
-
CHGIN
2.4.6
Charge IC Test
2.4.7
CFE and Charge IC Chipset Test Setup
Load
#2
V
I
V
Power
Supply #1
Ibat
JMP8
U1
U2
APPLICATION CIRCUIT
JMP1 JMP2 JMP3 JMP4 JMP5 JMP6 JMP7
BAT+
BAT -
DC+
DC-
F
AUL
T
BA
T+
OUT
DC
-
J3
J2
J1
HPA245 BQ2430x/1x/8x DSG EVM
DC
-
CHGIN
Test Summary
www.ti.com
6. JMP1: ON, JMP2: ON, JMP3: ON, JMP4: ON, JMP5: ON, JMP6: ON, JMP7: ON, JMP8: OFF
7. After the preceding steps, the test setup for HPA245 (bq2430x/1x/8x DSG EVM) is shown in
.
Figure 2. Charger IC Test Setup for HPA245 (bq2430x/1x/8x DSG EVM)
1. Enable output of Load #2
2. Enable output of PS#1
3. Increase the voltage of PS #1 to 5 V
±
0.1 V.
Observe
D4 off, D5 off, D6 on.
4. Uninstall JMP7 (enable U2).
Measure
Ibat = 200 mA
±
20 mA (For HPA245-001, -002, -003, -004, -013 only).
Measure
Ibat = 700 mA
±
70 mA (For HPA245-005, -006, -007, -008, -009, -010, -011, -012 only).
Observe
D4 on, D5 off, D6 on.
5. Disable the output of Load #2.
6. Disable the output of PS#1 and remove PS #1 from J3
1. Connect the output of power supply #1 to J1 (DC+, DC–).
2. Connect a voltage meter across J1 (DC+, DC–).
3. JMP1: ON, JMP2: ON, JMP3: OFF, JMP4: ON, JMP5: ON, JMP6: ON, JMP7: OFF, JMP8: ON.
4. After the preceding steps, the test setup for HPA245 (bq2430x/1x/8x DSG EVM) is shown in
.
Figure 3. Chipset Test Setup for HPA245 (bq2430x/1x/8x DSG EVM)
bq2430x/1x/8x DSG EVM (HPA245) for Li+ Charger Front-End Protection IC
6
SLUU291A – August 2007 – Revised April 2008