Test Summary
3. The bq2412x enters preconditioning mode if the battery is below the V
(LOWV)
threshold. In this mode,
the bq2412x precharges the battery with a low current programmed by the ISET2 pin. If the R
SET1
and
R
SET2
resistors are the same value, then the precharge is 1/10th the fast-charge current (I
PRE-CHG
=
1.33 A/10 = 133 mA) until the battery voltage reaches the V
(LOWV)
threshold or until the precharge timer
expires. If the timer expires, then the charge current is terminated and the bq24120x enters fault mode.
STAT1 and STAT2 (if available) LEDs turn off when in fault mode. Note that several noncharging
modes share this status state. Toggling input power or battery replacement resets fault mode.
4. Once the battery voltage is above the V
(LOWV)
threshold, the battery enters fast-charge mode. This
EVM is programmed for approximately 1.3 A of fast-charging current. The PG and STAT1 LEDs should
be on.
5. Once the battery reaches voltage regulation (4.2 V), the current tapers down as the battery reaches its
full capacity. The PG and STAT1 LEDs should be on.
6. When the current reaches the taper termination threshold, set by the R
SET2
resistor, the charge is
terminated. The PG LED should still be on, and the STAT1 LED should turn off and STAT2 LED turn
on.
7. If the battery discharges down to the recharge threshold, the charger starts fast-charging. The PG LED
should still be on, and the STAT2 LED should turn off and STAT1 LED turn on.
An alternative method of testing the EVM is with a source meter, that can sink or source current. This can
easily be adjusted to test each mode in place of a battery.
SLUU236A – March 2006 – Revised November 2007
Using the bq2412x (bqSWITCHER™) EVM
7