Texas Instruments LM3409 Demonstration Board LM3409EVAL/NOPB LM3409EVAL/NOPB Datenbogen

Produktcode
LM3409EVAL/NOPB
Seite von 43
t
i
(t)
 
ü
i
L-
PP
I
L-MAX
I
L-MIN
I
L
0
T
S
t
ON
 = DT
S
t
OFF
 = (1-D)T
S
D =
IN
V
x
O
V
SNVS602J – MARCH 2009 – REVISED MAY 2013
The average inductor current (I
L
) is equal to the average output LED current (I
LED
), therefore if I
L
is tightly
controlled, I
LED
will be well regulated. As the system changes input voltage or output voltage, duty cycle (D) is
varied to regulate I
L
and ultimately I
LED
. For any buck regulator, D is simply the conversion ratio divided by the
efficiency (
η
):
(1)
Figure 21. Ideal CCM Buck Converter Inductor Current i
L
(t)
CONTROLLED OFF-TIME (COFT) ARCHITECTURE
The COFT architecture is used by the LM3409/09HV to control I
LED
. It is a combination of peak current detection
and a one-shot off-timer that varies with output voltage. D is indirectly controlled by changes in both t
OFF
and t
ON
,
which vary depending on the operating point. This creates a variable switching frequency over the entire
operating range. This type of hysteretic control eliminates the need for control loop compensation necessary in
many switching regulators, simplifying the design process and providing fast transient response.
Adjustable Peak Current Control
At the beginning of a switching period, PFET Q1 is turned on and inductor current increases. Once peak current
is detected, Q1 is turned off, the diode D1 forward biases, and inductor current decreases.
shows how
peak current detection is accomplished using the differential voltage signal created as current flows through the
current setting resistor (R
SNS
). The voltage across R
SNS
(V
SNS
) is compared to the adjustable current sense
threshold (V
CST
) and Q1 is turned off when V
SNS
exceeds V
CST
, providing that t
ON
is greater than the minimum
possible t
ON
(typically 115ns).