Texas Instruments Advanced bqMTester Multi-Station Test and Program Board Texas Instruments ADVANCED-BQMTESTER ADVANCED-BQMTESTER Datenbogen

Produktcode
ADVANCED-BQMTESTER
Seite von 62
Advanced bqMTester Instructions
(a) Select the Update VTI screen to calibrate the HPA495 voltage, current, and temperature sources
used to calibrate the modules.
(b) Start testing. Log data is displayed on the log screens and stored to a file (as setup in Step 3 of this
section).
4.2
Detailed Instructions
This section describes the entire process of setting up the bqMTester software and hardware for a single
station and a Texas Instruments bq20zxx EVM. It is recommended to start with one station and the Texas
Instruments EVM to prevent setup complications. Once the setup for one station and the Texas
Instruments EVM is complete, the process can be repeated with your fuel gauge and multiple stations.
4.2.1
Generate ROM File
NOTE:
The ROM file is programmed into every device that uses the Advanced bqMTester, so it is
very important that it is done correctly.
Create the ROM file using bqEASY in bqEVSW. If bqEASY is not available for your device, use the flow
detailed in
to create the ROM file. It is recommended to use bqEASY whenever possible to
generate the ROM file because it reduces the chances of mistakes in this very critical process.
The ROM file is a data flash image file. It has two parts.
1. Header information that includes the fuel gauge type and firmware version. This is used by bqMTester
to protect against programming an incompatible data flash image into a fuel gauge, which could
permanently damage the fuel gauge.
2. A binary image of the entire data flash. It does not include the firmware image, only the data flash. This
cannot be used to reprogram firmware into a fuel gauge.
4.2.2
Software Installation
The TIbqMultiStationNB2.00Setup.exe file installs all required software, drivers, and DLL files for proper
software operation. To install the software:
1. Do not connect any EV2x00s to the PC before installing software. If any are connected, disconnect
them now.
2. Download software from the bqMTester page on the
web site.
3. Unzip the file downloaded in Step 2. Double-click TIbqMultiStationNMx.xxSetup.exe" ("x.xx"
depends on the software version).
4. Click Next at the welcome screen.
7
SLUU397A
February 2011
Revised May 2011
Advanced bqMTester
Copyright
©