Texas Instruments BQ24314EVM - BQ24314 Evaluation Module BQ24314EVM BQ24314EVM Datenbogen

Produktcode
BQ24314EVM
Seite von 14
2
Test Summary
2.1
Definitions
2.2
Equipment
2.2.1
Power Supplies
2.2.2
Load #1
2.2.3
Load #2
2.2.4
Meters
www.ti.com
Test Summary
This procedure details how to configure the evaluation board. On the test procedure, the following naming
conventions are followed. See
the schematic for details.
VXXX :
External voltage supply name (VIN, VBAT, VOUT)
LOADW:
External load name (LOADR, LOADI)
V(TPyyy) :
Voltage at internal test point TPyyy. For example, V(TP1) means the voltage at TP1.
V(Jxx):
Voltage at jack terminal Jxx.
V[TP(XXXXX)]:
Voltage at test point XXXXX. For example, V(ACDET) means the voltage at the test
point which is marked as ACDET.
V(XXX, YYY):
Voltage across point XXX and YYY.
I[JXX(YYY)]:
Current going out from the YYY terminal of jack XX.
Jxx(BBB):
Terminal or pin BBB of jack xx
Jxx ON :
Internal jumper Jxx terminals are shorted
Jxx OFF:
Internal jumper Jxx terminals are open
Jxx (-YY-) ON:
Internal jumper Jxx adjacent terminals marked as YY are shorted
Measure:
A,B Check specified parameters A, B. If measured values are not within specified
limits, the unit under test has failed.
Observe:
A,B Observe if A, B occur. If they do not occur, the unit under test has failed.
Assembly drawings have location for jumpers, test points, and individual components.
Power Supply #1 (PS#1): a power supply capable of supplying 20 V at 2 A is required.
Power Supply #2 (PS#2): a power supply capable of supplying 5 V at 1 A is required.
A 10-V (or above), 2-A (or above) electronic load that can operate at constant current mode.
A 10-V (or above), 2-A (or above) electronic load that can operate at constant voltage mode.
Four Fluke 75 multimeters, (equivalent or better)
Or: Three equivalent voltage meters and one equivalent current meter. The current meters must be
capable of measuring 2-A+ current.
SLUU291A – August 2007 – Revised April 2008
bq2430x/1x/8x DSG EVM (HPA245) for Li+ Charger Front-End Protection IC