Texas Instruments BQ24150AEVM - BQ24150A Evaluation Module BQ24150AEVM BQ24150AEVM Datenbogen

Produktcode
BQ24150AEVM
Seite von 14
To
Computer
USB port
USB
Interface
Adapter
I/O
USB
T
exasInstruments
©2006
10-pin
Ribbon
Cable
To EVM
Test Summary
2.2.7
SOFTWARE
Unzip BQ2415xSetup.zip and double click on the
SETUP.EXE
file. Follow the installation steps.
2.3
Equipment Setup
(A) Set the power supply #1 for 5V
±
100mV DC, 2.0
±
0.1A current limit and then turn off supply.
(B) Connect the output of power supply #1 in series with a current meter (multimeter) to J1 (DC+, DC
).
(C) Connect a voltage meter across J1 (DC+, DC
).
(D) Connect the Load #2 in series with a current meter (multimeter) to J2 (BAT+, BAT
). Make sure a
voltage meter is connected across J2 (BAT+, BAT
). Turn on the Load #2. Use the constant voltage
mode. Set the output voltage to 2.5V.
(E) Turn off Load #2.
(F) Connect J5 to HPA172 kit by 10-pin ribbon cable. Connect the USB port of the HPA172 kit to the USB
port of the computer. The connections are shown in
.
Figure 1. Connections of the HPA172 Kit
(G) Installed jumpers per
Table 1. Factory Jumper Settings
Spin
JMP1
JMP2
JMP3
JMP4
JMP5
HPA256-001
(-LED-) ON
(-LO-) ON
ON
OFF
ON
(bq24150)
HPA256-002
(-LED-) ON
(-LO-) ON
ON
OFF
ON
(bq24151)
HPA256-003
(-LED-) ON
(-LO-) ON
ON
OFF
ON
(bq24152)
HPA256-004
(-LED-) ON
(-LO-) ON
ON
OFF
ON
(bq24150A)
HPA256-005
(-LED-) ON
(-LO-) ON
ON
OFF
ON
(bq24151A)
4
bq24150/150A/151/151A/152 YFF EVM (HPA256)
SLUU321C
June 2008
Revised June 2011
Copyright
©
2008
2011, Texas Instruments Incorporated