Texas Instruments BQ24071 Evaluation Module BQ24071EVM BQ24071EVM Datenbogen

Produktcode
BQ24071EVM
Seite von 15
www.ti.com
3
Performance Specification Summary
4
Test Summary
4.1
Equipment
4.2
Equipment Setup
10
to 30
W
W
J4
J1
5.25 VDC
AC
GND
DMM
#1
DMM
#3
P/A
#1
DMM
#2
J2
+
+
+
TS
OUT
BAT+
B0136-01
(DC–)
BAT–
GND
HPA180
UUT
®
TP4
LDO
bq24070/1 Charger EVM
Li-Ion, Single-Cell,
1- to 2- A h Capacity
×
Performance Specification Summary
summarizes the performance specifications of the EVM.
Table 1. Performance Specification Summary For bq24070/1 EVM
SPECIFICATION
TEST CONDITIONS
MIN
TYP
MAX
UNITS
Input dc voltage, V
I(AC)
4.8
5
6.5
V
Input dc USB voltage, V
I(USB)
5
Battery charge current, I
O(CHG)
1
2+
A
Power dissipation, bq24070/1 IC, 1 cell
P
DISS
= (V
IN
– V
OUT
)Iout + (V
IN
See
(1)
W
V
BAT
)I
BAT
+ (V
IN
– V
LDO
)I
LDO
(1)
The HPA180 (bq24070/1) thermal design is optimized (8
+
vias, 0.031-inch PWB, 2 oz. copper) to give
θ
JA
~ 27°C/W.
This section covers the setup and tests performed in evaluating the EVM.
Power supply (5.25 ± 0.25 VDC), current limit set to 2.0 A ± 0.2 A for AC input to the UUT
Three Fluke 75 DMMs (equivalent or better)
Oscilloscope, Model TDS220 (equivalent or better)
Preset the UUT power supply voltage and current prior to connection to UUT; turn off the power supply
and connect the supply to J1-IN/GND (+ to IN and – to GND).
Connect a 10-
Ω
to 30-
Ω
load to J4-OUT/GND.
Connect a fully discharged (< 2.8-VDC) single-cell Li-ion or Li-polymer battery to J2-BAT+/BAT–.
Connect the DMMs as shown in
Figure 1. Test Diagram
SLUU248A – May 2006 – Revised August 2006
bq24070/1 1.5-A Single-Chip Li-Ion and Li-Pol Charge Management IC EVM
3