Texas Instruments DS80PCI800EVK Evaluation Module DS80PCI800EVK/NOPB DS80PCI800EVK/NOPB Datenbogen

Produktcode
DS80PCI800EVK/NOPB
Seite von 11
 
 
 
 
 October 2012 
 
 
 
 
 
 
 
SNLU119  
 
 
 
2.  Setup: 
 
2.1. Connect J19:  VIN  = 3.3V or VDD = 2.5V and GND 
 
For VIN = 3.3V: 
 
Set SW7 pin1 (VDD_SEL) to the ON position (enable internal LDO regulator) and float VDD at J19. 
 
For VDD = 2.5V: 
 
Set SW7 pin1 (VDD_SEL) to the OFF positions (disable internal LDO regulator) and float VIN at J19. 
2.2. Set jumper – J20 for VIH connection to VIN or VDD 
 
2.3. Connect 50 Ohm SMA cables to the board 
 
The input signals J1 to J8 can be connected from a pattern generator.  
 
The output signals J9 to J16 can be connected to a scope. 
 
Top 2 – B channel:       J1 – IN_B2+, J2 – IN_B2-  
  J9 – OUT_B2+, J10 – OUT_B2- 
 
 
 
        J3 – IN_B3+, J4 – IN_B3-  
  J11 – OUT_B3+, J12 – OUT_B3- 
 
Bottom 2 – A channel: J5 – IN_A0+, J6 – IN_A0-  
  J13 – OUT_A0+, J14 – OUT_A0- 
 
 
 
        J7 – IN_A1+, J8 – IN_A1-  
  J15 – OUT_A1+, J16 – OUT_A1- 
 
2.4. Set the control pins for normal operation 
 
SW7 – PRSNT = 0 (enables the device): set switch pin2 to the ON position. 
 
SW9 – RXDET = F (continuous receiver detection): set switches (3-2-1) = (OFF-OFF-OFF). 
 
            RXDET = 1 (50 ohm input termination): set switches (3-2-1) = (OFF-OFF-ON). 
 
SW9 – RATE = 1 (GEN3 mode with DEM control): set switches (6-5-4) = (OFF-OFF-ON). 
            RATE = F (enable rate detection for GEN1,2,3 with DEM control): set switches (6-5-4) to (OFF-OFF-OFF). 
 
            RATE = R (GEN3 mode without DEM control): set switches (6-5-4) = (OFF-ON-OFF). 
 
            RATE = 0 (GEN1,2 mode with DEM control): set switches (6-5-4) = (ON-OFF-OFF). 
 
SW6 – SD_TH = F (default signal detect threshold level): set switches (3-2-1) = (OFF-OFF-OFF). 
 
SW6 – RES = F (normal operation): set switches (6-5-4) = (OFF-OFF-OFF). 
 
2.5. Set the input equalization level 
 
For external pin mode control of the equalization level:  
 
Set ENSMB = 0 (1kohm to GND) by using the SW2 (3-2-1) = (ON-OFF-OFF). 
 
SW4 pin1,2 must be set to the OFF positions, so the SMBUS signals are disconnected. 
 
Refer to Table 1 for information on the 3 switch settings for the 4 level input. 
 
 
 
Example:  
 
Set EQB[1:0] with SW1 for the B bank of inputs (top 4 inputs of DS80PCI800). 
 
SW1 (6-5-4), (3-2-1) = (OFF-ON-OFF), (OFF-ON-OFF) = EQB[1:0] = R,R = 14.6 dB at 4 GHz (level 6). 
  
Set EQA[1:0]  with SW8 for the A bank of inputs (bottom 4 inputs of DS80PCI800). 
 
SW8 (6-5-4), (3-2-1) = (OFF-ON-OFF), (OFF-ON-OFF) = EQA[1:0] = R,R = 14.6 dB at 4 GHz (level 6). 
 
 
Table 3: 16 EQ settings when in pin mode 
Level 
EQA/B[1:0] 
SW1 - EQB[1:0]  
SW8 - EQA[1:0] 
EQ (dB) at 4 GHz 
  
 
  
0, 0 
ON 
OFF 
OFF 
ON 
OFF 
OFF 
4.9 
0, R 
ON 
OFF 
OFF 
OFF 
ON 
OFF 
7.9 
0, F 
ON 
OFF 
OFF 
OFF 
OFF 
OFF 
9.9 
0, 1 
ON 
OFF 
OFF 
OFF 
OFF 
ON 
11.0 
R, 0 
OFF 
ON 
OFF 
ON 
OFF 
OFF 
14.3 
R, R 
OFF 
ON 
OFF 
OFF 
ON 
OFF 
14.6 
R, F 
OFF 
ON 
OFF 
OFF 
OFF 
OFF 
17.0 
R ,1 
OFF 
ON 
OFF 
OFF 
OFF 
ON 
18.5 
F ,0 
OFF 
OFF 
OFF 
ON 
OFF 
OFF 
18.0 
10 
F, R 
OFF 
OFF 
OFF 
OFF 
ON 
OFF 
22.0 
11 
F, F 
OFF 
OFF 
OFF 
OFF 
OFF 
OFF 
24.4 
12 
F, 1 
OFF 
OFF 
OFF 
OFF 
OFF 
ON 
25.8 
13 
1, 0 
OFF 
OFF 
ON 
ON 
OFF 
OFF 
27.4 
14 
1, R 
OFF 
OFF 
ON 
OFF 
ON 
OFF 
29.0 
15 
1, F 
OFF 
OFF 
ON 
OFF 
OFF 
OFF 
31.4 
16 
1, 1 
OFF 
OFF 
ON 
OFF 
OFF 
ON 
32.7