Texas Instruments TSC2006EVM-PDK Evaluation Module TSC2006EVM-PDK TSC2006EVM-PDK Datenbogen

Produktcode
TSC2006EVM-PDK
Seite von 25
www.ti.com
6.4.2.1
ADC Configuration (CFR0)
Kit Operation
Figure 4. Configuration Tab of Software GUI Screen
This section controls the parameters in CFR0. Each button or selection controls one parameter.
Pen Control Mode
The button controls if the touch data acquisition is started or initialized by host processor's command
(manually) or by a touch on the screen (automatically). Default by touching screen.
Stop ADC
This button can stop TSC2006 ADC, or put the ADC to normal running mode. Default to normal
running mode.
Resolution
Selects between 10- and 12-bit resolution. Note that, the bit #2 of CB1 also controls the resolution and
thus you may need to double-check the settings at both places to make sure they are consistent.
Default setting is 12-bit resolution.
Conversion Clock
The internal clock which runs the A/D converter can run at 4, 2, or 1 MHz. Note that, when running at 4
MHz, only 10-bit resolution is possible, but 12-bit is not. Thus, you may need to check resolution
setting after selecting 4-MHz conversion clock. By default, the clock is running at 2 MHz.
Panel Voltage Stabilization Time
This is the time that the TSC2006 allows for the touch screen to settle after turning the drivers on.
SLAU200 – January 2007
TSC2006EVM and TSC2006EVM-PDK
11