Texas Instruments TRF3761 Demonstration Fixture TRF3761EVM-X TRF3761EVM-X Datenbogen

Produktcode
TRF3761EVM-X
Seite von 18
www.ti.com
2.2
The Controls
Use the spinner buttons to adjust the divide by ratio.
Type in the value of R27 on the board.
Make sure this button’s indicator is green.
Make sure this button s indicator is green.
Type in the frequency of your reference in MHz.
Type in the step frequency you require.
Use the spinner buttons to set.
Type in the frequency of interest.
Use spinner buttons to change the frequency divider.
Use execute button to run program.
Shows the output frequency of TRF3761
Software Setup
The left side of the main control screen is where inputs can be adjusted.
Fcrystal is the reference used on the EVM. It can between 10 MHz to 104 MHz.
Fpfd is the phase frequency detector frequency and sets the frequency step size. For example, if the
main frequency is 2000 MHz and the Fpfd is 200 kHz, then the next frequency step can be 2000.2
MHz.
Prescalar Div Ratio is the ratio used in the Fout equation, Fout = Fpfd (A+PB), where the numerator of
the Prescalar Div Ratio is equal to P, and A and B are calculated. For more information, see Appendix
A.
Rbias is used for a calculation which is on the right side of the Main Control Screen in the window
Icp(Rbias).The value of Rbias is set to the same value as R27 on the EVM board is 2.73 k
Ω
. The
resistor value can be changed on the board if a different charge pump current is desired.
Icp sets the amount of current on the charge pump as well. Eight setting are used to increase and
decrease the current; they are 0.7, 1.4, 2.1, 2.8, 3.5, 4.2, 4.9, and 5.6. These numbers represent the
current seen if a 4.75-k
Ω
resistor is used. The calculation to determine the desired Icp
actual
is
[Icp(4.75k)]/Rbias = Icp
actual
, which should give the same answer as the Icp(Rbias) on the right side
calculations.
Fvco is the output frequency of VCO.
Output Mode sets the frequency divider. For example, if 500 MHz is required, then set the Fvco to
2000 MHz and the Output Mode to “/4”.
The Selected Output window at the bottom by the Execute button shows the output frequency that the
user sets up.
To enter the data into the TRF3761, press the Execute button. Once pressed, the output changes to
the frequency shown in the Selected Output window.
TRF3761 EVM User's Guide
8
SLWU035A – February 2007 – Revised March 2007