Texas Instruments Evaluation Module for UCD9224 Digital PWM System Controller UCD9224EVM-464 UCD9224EVM-464 Datenbogen

Produktcode
UCD9224EVM-464
Seite von 28
www.ti.com
Software Setup
6
Software Setup
Accessing the UCD9224EVM-464’s configuration, control and monitoring capabilities with the Fusion
Digital Power Designer software tool requires a one-time software setup per host system.
6.1
Fusion Digital Power Designer Software (Fusion GUI) Installation
Place the Fusion Digital Power Designer Software (Fusion GUI) Installer zip file (UCD9224EVM-464
Software Files) in a known location on the host computer to be used for EVM configuration/test. Unzip the
installation files for the Fusion Digital Power Designer Software by double clicking the zip file.
Double click the unzipped TI-Fusion-Digital-Power-Designer-1.8.6.exe file and proceed through the
installation by accepting the installer prompts and the license agreement. Use the Fusion GUI installer’s
suggested default installation locations to complete the install.
When the Fusion GUI installation reaches the finished window, uncheck the launch application check box
and close the window.
7
Test Procedure
The UCD9224EVM-464 is provided with a default configuration that will allow the user to immediately
power up the EVM and begin testing as either a stand-alone power solution or as a “networked” power
system when accessing the PMBus™ interface.
7.1
Test Setup
1. Set the external input power supply’s output voltage to 12 V +/-0.5 V and current limit the supply at 5.0
A. Ensure the output voltage is disabled.
2. Attach supply connection leads (AWG 20 minimum) between the external power supply and the input
voltage connector (J1) on the EVM following the polarity settings shown in the Recommended Test
Setup (
3. Set both Electronic Load A and B to constant current loading and adjust their loading currents to 10.0
A +/- 0.1 A each.
4. Attach leads (AWG 16 minimum) between the Electronic Load A inputs and the target EVM’s V
OUT1
(J6)
connector following the polarity settings shown in the Recommended Test Setup (
5. Attach leads (AWG 16 minimum) between the Electronic Load B inputs and the target EVM’s V
OUT2
(J5)
connector following the polarity settings shown in the Recommended Test Setup (
6. Ensure that both electronic loads have their loads enabled.
13
SLUU443 – March 2011
UCD9224EVM-464 Digitally Controlled Dual-Rail POL
© 2011, Texas Instruments Incorporated