Texas Instruments LM3447 Flyback Controller for LED Lighting Evaluation Module Board LM3447-A19-230VEVM LM3447-A19-230VEVM Datenbogen

Produktcode
LM3447-A19-230VEVM
Seite von 30
Test Procedure
6
Test Procedure
6.1
Line/Load Regulation and Efficiency Measurement Procedure
1. Connect EVM per
above. An external LED load must be used to start up the EVM.
2. Prior to turning on the AC source, set the voltage to 190 V
RMS
.
3. Turn on the AC source.
4. Record the output voltage and current readings from Voltmeter 2 and output current reading from
Ammeter 2 and input voltage reading from Voltmeter 1 and current from Ammeter 1.
5. Increase output voltage by 5 V
RMS
.
6. Repeat steps 4 and 5 until 265 V
AC
is reached.
7. Refer to
for shutdown procedure.
6.2
Equipment Shutdown
1. Turn off equipment.
2. Make sure capacitors are discharged.
6.3
EVM Phase Angle Decode vs LED Current
1. Connect EVM per
above. An external LED load must be used to start up the EVM.
2. Prior to turning on the AC source, set the voltage to 230 VRMS.
3. Connect scope probe to EVM per
above to bridge rectifier output.
4. Turn on the AC source.
5. Record the output voltage and current readings from Voltmeter 2 and output current reading from
Ammeter 2 and input voltage reading from Voltmeter 1 and current from Ammeter 1.
6. Set dimmer to minimum setting and vary by 1.0 msec till 8 msec is reached and record in 5 above.
7. Refer to
for shutdown procedure.
NOTE:
The scope must be isolated.
7
SLUU978 – June 2012
LM3447-A19-230VEVM is a Phase-Dimmable, Primary-Side Regulated LED
Driver
Copyright © 2012, Texas Instruments Incorporated