Texas Instruments TLV320AIC34 Evaluation Module (EVM) and USB motherboard TLV320AIC34EVM-K TLV320AIC34EVM-K Datenbogen

Produktcode
TLV320AIC34EVM-K
Seite von 61
www.ti.com
4.8
AGC Tab
TLV320AIC34EVM Software
Figure 9. AGC Tab
The AGC tab (see
) consists of two identical sets of controls, one for the left channel and the
other for the right channel. The AGC function is described in the
data sheet.
The AGC can be enabled for each channel using the Enable AGC button. Target gain, Attack time in
milliseconds, Decay time in milliseconds, and the Maximum PGA Gain Allowed can all be set,
respectively, using the four corresponding knobs in each channel.
The TLV320AIC34 allows for the Attack and Decay times of the AGC to be setup in two different modes,
standard and advanced. The Left/Right AGC Settings button determines the mode selection. The
Standardmode provides several preset times that can be selected by adjustments made to the Attackand
Decayknobs. If finer control over the times is required, then the Advanced mode is selected to change to
the settings. When the Advanced mode is enabled, two tabs should appear that allow separate, advanced
control of the Attack and Delay times of the AGC (see
and
). These options allow
selection of the base time as well as a multiplier to achieve the actual times shown in the corresponding
text box. The Use advanced settings? button should be enabled to program the registers with the correct
values selected via the pull-down options for base time and multiplier.
20
TLV320AIC34EVM-K
SLAU232 – December 2007