L M K 0 4 8 X X   E V A L U A T I O N   B O A R D   O P E R A T I N G   I N S T R U C T I O N S  
 
 
 
 
 
30 
VCO Frequency (MHz) 
n/a 
The VCO Frequency should be the OSCin 
frequency, except when operating in Dual 
PLL with 0-delay feedback.  This value is 
calculated as: 
VCO Freq (OSCin freq) = PLL1 PDF * 
PLL1_N. 
In Dual PLL mode with 0-delay feedback, 
the VCO frequency should be set to the 
feedback clock input frequency.  See the 
section Setting the PLL1 VCO Frequency 
and PLL2 Reference Frequency 
for details. 
R Counter  
PLL1_R 
PLL1 R Counter value (1 to 16383). 
N Counter  
PLL1_N 
PLL1 N Counter value (1 to 16383). 
Phase Detector Polarity 
PLL1_CP_POL 
PLL1 Phase Detector Polarity.   
Click on the polarity sign to toggle polarity 
“+” or “–”. 
Charge Pump Gain 
PLL1_CP_GAIN 
PLL1 Charge Pump Gain. 
Left-click/right-click to increase/decrease 
charge pump gain (100, 200, 400, 1600 uA). 
Charge Pump State 
PLL1_CP_TRI 
PLL1 Charge Pump State.   
Click to toggle between Active and Tri-State. 
 
Setting the PLL1 VCO Frequency and PLL2 Reference Frequency 
When operating in Dual PLL mode without 0-delay feedback, the VCO frequency value on the 
PLL1 tab must match the Reference Oscillator (OSCin) frequency value on the PLL2 tab; 
otherwise, the one or both PLLs may be out of lock.  Updating the Reference Oscillator 
frequency on the PLL2 tab will automatically update the value of OSCin_FREQ on the 
Bits/Pins tab.   
 
However, when operating in Dual PLL mode with 0-delay feedback, it may be valid for the VCO 
frequency value on the PLL1 tab to be different from the Reference Oscillator (OSCin) 
frequency value on the PLL2 tab.   This is because in 0-delay mode, the PLL1 feedback clock is 
taken from an output clock instead of the OSCin clock.  For example, if the CLKin frequency (to 
PLL1_R) is 30.72 MHz, the 0-delay feedback clock frequency (to PLL1_N) is 30.72 MHz, and 
the VCXO frequency is 122.88 MHz, then the VCO frequency value on the PLL1 tab should be 
30.72 MHz (0-delay feedback frequency) and the Reference Oscillator frequency value on the 
PLL2 tab should be 122.88 MHz (VCXO frequency).  Because of the mismatched frequencies, a 
warning message will indicate this condition on the Clock Outputs tab but may be disregarded 
in a case like this.