ADC3101 Control Software
Figure 14. Command-line Interface Panel Record Function
4.2
Status Flags Panel
The TLV320ADC3101 status flags can monitored in the Status Flags panel (
which is located
below the Panel Selection Tree. Pressing the POLLING button continuously reads all the registers
relevant to each flag and updates those flags accordingly. The rate at which the registers are read can be
modified by changing the value in the Polling Interval numeric control. Note that a smaller interval
reduces responsiveness of other controls, especially volume sliders, due to bandwidth limitations. By
default, the polling interval is 200 ms and can be set to a minimum of 20 ms.
The Sticky Flags tab contains indicators whose corresponding register contents clear every time a read is
performed to that register. To read all the sticky flags, click the Read Sticky Flags button.