Texas Instruments TLV320ADC3101 Evaluation Module (EVM) and USB motherboard TLV320ADC3101EVM-K TLV320ADC3101EVM-K Datenbogen

Produktcode
TLV320ADC3101EVM-K
Seite von 46
USB-MODEVM Protocol
If the command is sent with no problem, the returning byte [0] is the same as the sent one logically ORed
with 0x20 - in the preceding first example, the returning packet is:
[0]0x31
[1]0xA0
[2]0x02
[3]0x05
[4]0xAA
[5]0x55
If for some reason the interface fails (for example, the I
2
C device does not acknowledge), it comes back
as:
[0]0x51
interface | INTF_ERROR
[1]0xA0
[2]0x02
[3]0x05
[4]0xAA
[5]0x55
If the request is malformed, that is, the interface byte (byte [0]) takes on a value which is not as previously
described, the return packet is:
[0]0x93
the user sent 0x13, which is not valid, so 0x93 returned
[1]0xA0
[2]0x02
[3]0x05
[4]0xAA
[5]0x55
The preceding examples used writes. Reading is similar:
Read two bytes from device starting at register 5 of an I
2
C device with address A0:
[0]0x01
[1]0xA0
[2]0x02
[3]0x05
42
USB-MODEVM Protocol
SLAU267A – December 2008 – Revised October 2012
Copyright © 2008–2012, Texas Instruments Incorporated