ADS1220EVM Hardware Details
5.3
Clock Source Options
The ADS1220 clock can come from one of several sources: the internal oscillator of the ADS1220, an
oscillator installed at U3, a clock supplied by a processor via U8, or an external clock source connected to
J8. The default configuration is to use the internal oscillator of the ADS1220.
If a precision oscillator is installed at U3, a 10-nF capacitor should also be installed at C21. To allow the
clock to pass through multiplexer U2, the enable jumper must be installed at JP4. A standard 0.1-inch
pitch header and shorting block can be installed at JP4 for this purpose. A more permanent solution is
accomplished by soldering a small piece of wire to the terminals of JP4. JP4 can be found near the center
of the top edge of the EVM.
An external clock can also be attached to connector J8. The clock signal must conform to the 3.3-V logic
used for the EVM. A clock provided by the controller is not available at this time.
5.4
Digital Interface
Primary control of the ADS1220 is via MSP430 controller U7. U7 communicates to the ADS1220 to read
and write register settings as well as to retrieve conversion data. U7 also responds to commands sent
from the ADS1220EVM plug-in when using ADCPro. When the EVM is plugged into an available USB
port, U7 enumerates as a communications device class (CDC) peripheral operating as a virtual COM port.
The USB physical connection is through J9, which is a standard type A connector located on the right side
of the ADS1220EVM. J9 can be plugged directly into an available USB port connector of the computer. An
extension cable can also be used instead of the direct connection.
U7 uses two hardware peripherals to control devices on the ADS1220EVM. One peripheral uses SPI™ to
communicate with the ADS1220. The second peripheral is an I
2
C™ master. The primary purpose for the
I
2
C is for communication to the EEPROM (U4) that contains specific information regarding the
configuration of the EVM. I
2
C devices can also be connected to J5, but additional changes to the firmware
are required for communication. See
for details on these pins.
If firmware changes or updates are required for U7, two update methods are possible. One method is via
JTAG connector J10 (uninstalled). See
for details on these pins. The second method is by
using the bootstrap loader (BSL) of the MSP430. For further information, see the Texas Instruments web
site at
Alternative control of the ADS1220 from other processors is possible by either connecting the processor
control signals to the test points for the digital signals, or by using the JAC and JDB connectors located on
the bottom-side of the ADS1220EVM. See
for details on these pins and their operation.
5.4.1
Auxiliary Device Connector, J5
The ADS1220 allows the I
2
C serial interface to be used with an external device. To use this option, the
controller firmware must be modified. Optional connector J5 must be installed. The J5 connector is similar
to J4. A Samtec TSM-102-01-L-DV-P or equivalent can be used.
provides details on the J5 pins.
Table 8. J5: Auxiliary Connector
Function
Signal Name
Pin Number (J5)
Analog ground
AGND
3
Analog supply
AVDD
1
Serial clock
SCL
4
Serial data
SDA
2
13
SBAU203 – July 2013
ADS1x20EVM
Copyright © 2013, Texas Instruments Incorporated