Command Line Interface Tab
Kit Operation
A simple scripting language controls the TAS1020 on the USB-MODEVM from the LabView™-based PC
software. The main program controls, described previously, do nothing more than write a script which is
then handed off to an interpreter which sends the appropriate data to the correct USB endpoint. Because
this system is script-based, provision is made in this tab for the user to view the scripting commands that
are created as the controls are manipulated, as well as load and execute other scripts that have been
written and saved (see
). This design allows the software to be used as a quick test tool or to
help provide troubleshooting information in the rare event that the user encounters problem with this EVM.
Figure 22. Command Line Interface Tab
A script is loaded into the command buffer, either by operating the controls on the other tabs or by loading
a script file. When executed, the return packets of data which result from each command will be displayed
in the Read Data array control. When executing several commands, the Read Data control shows only the
results of the last command. If you to see the results after every executed command, use the logging
function described below.