4.2
USB-MODEVM Interface Power
5
EVM Operation
5.1
Analog Input
5.2
Analog Output
5.3
Digital Control
EVM Operation
The USB-MODEVM Interface board can be powered from several different sources:
USB
6VDC-10VDC AC/DC external wall supply (not included)
Lab power supply
When powered from the USB connection, JMP6 should have a shunt from pins 1–2 (this is the default
factory configuration). When powered from 6V-10VDC, either through the J8 terminal block or the J9
barrel jack, JMP6 should have a shunt installed on pins 2–3. If power is applied in any of these ways,
onboard regulators generate the required supply voltages and no further power supplies are necessary.
If lab supplies are used to provide the individual voltages required by the USB-MODEVM Interface, JMP6
should have no shunt installed. Voltages are then applied to J2 (+5VA), J3 (+5VD), J4 (+1.8VD), and J5
(+3.3VD). The +1.8VD and +3.3VD can also be generated on the board by the onboard regulators from
the +5VD supply; to enable this configuration, the switches on SW1 need to be set to enable the
regulators by placing them in the ON position (lower position, looking at the board with text reading
right-side up). If +1.8VD and +3.3VD are supplied externally, disable the onboard regulators by placing
SW1 switches in the OFF position.
Each power supply voltage has an LED (D1-D7) that lights when the power supplies are active.
This section provides information on the analog input and output, digital control, and general operating
conditions of the TLV320AIC31EVM.
The analog input sources can be applied directly to J1 (top or bottom side) or through signal conditioning
modules available for the modular EVM system.
The analog inputs may also be accessed through J8 and and screw terminals J6, J7, and J10.
The analog outputs from the TLV320AIC31 are available on J1 and J2 (top or bottom). They also may be
accessed through J9, J11, J12, J13, and J14.
The digital control signals can be applied directly to J4 and J5 (top or bottom side). The modular
TLV320AIC31EVM can also be connected directly to a DSP interface board, such as the
5-6KINTERFACE or HPA-MCUINTERFACE, or to the USB-MODEVM Interface board if purchased as part
of the TLV320AIC31EVM-PDK. See the product folder for
or the
for a current list of
compatible interface and/or accessory boards.
6
TLV320AIC31EVM and TLV320AIC31EVM-PDK User's Guide
SBAU115 – November 2005