Cell Phone Call
The effect of electromagnetic interference is demonstrated in a setup where a cell phone causes
interference with a pressure sensor application (
). This application needs two op amps and
therefore a dual op amp is used. The experiment is performed on two different dual op amps as in the
previous example: a typical standard op amp and the dual LMV852 EMI hardened op amp. The op amps
are connected to a single supply. The cell phone is placed in a fixed position a couple of centimeters from
the op amps.
When the cell phone is called, the op amps detect the RF signal transmitted by the cell phone. The
resulting effect on the output voltage of the second op amp is depicted in
The difference between the two types of dual op amps is clearly visible. The typical standard dual op amp
has an output voltage shift (disturbing signal) larger than 1V as a result of the RF signal transmitted by the
cell phone. The LMV852 EMI hardened op amp does not show any significant disturbances.
It should be noted that the relative size of the disturbances in the output signal for those two cases, is
equal to the difference of the EMIRR for the two dual op amps used. So, the EMIRR enables an early
selection of components for building an EMI robust application.