Texas Instruments DRV2605EVM-CT Benutzerhandbuch

Seite von 35
ERM
Or
LRA
OUT+
OUT-
100k
100k
470 pF
470 pF
Ch1-Ch2
(Differential )
Oscilloscope
Ch1
Ch2
100k
470pF
100k
470pF
OUT
OUT-
OUT+
From DRV2605
Measurement and Analysis
5
Measurement and Analysis
The DRV2605 uses PWM modulation to create the output signal for both ERM and LRA actuators. To
measure and observe the DRV2605 output waveform, connect an oscilloscope or other measurement
equipment to the filtered output test points, “OUT+” and “OUT–".
Figure 22. Terminal Block and Test Points
The DRV2605 drives LRA and ERM actuators using a 20-kHz PWM modulated waveform, but only the
frequencies around the LRA resonant frequency, or the ERM DC drive voltage, are relevant to the haptic
actuator vibration. The higher frequency switching content does not contribute to the vibration strength of
the actuator and can make it difficult to interpret the modulated output waveform on an oscilloscope. The
oscilloscope image
shows the DRV2605 unfiltered waveform and
shows a filtered
version used for observation and measurement.
Figure 23. DRV2605 Unfiltered Waveform
Figure 24. DRV2605 Filtered Waveform
If the DRV2605EVM-CT filter is not used, TI recommends using a first-order, low-pass filter with a cutoff
between 1 and 3.5 kHz.
shows a recommended output filter for use while measuring and
characterizing the DRV2605 in the lab.
Figure 25. Measuring the DRV2605 Output Signal With an Analog Low-Pass Filter
21
SLOU348B – January 2013 – Revised March 2014
DRV2605EVM-CT ERM and LRA Haptic Driver Evaluation Kit
Copyright © 2013–2014, Texas Instruments Incorporated