TLV320AIC3106EVM Software
4.3
Front Page Indicators and Functions
illustrates the main screen of the EVM software. The indicators and buttons located above the
tabbed section of the front page are visible regardless of which tab is currently being selected.
At the top left of the screen is an Interface indicator. This indicator shows which interface is selected for
controlling the TLV320AIC3106 , either I
2
C or SPI.
To the right of the Interface indicator is a group box called . This box indicates where the firmware being
used is operating from—in this release, the firmware is on the USB-MODEVM, so the user should see
USB-MODEVM in the box labeled Located On:. The version of the firmware appears in the Version box
below this.
To the right, the next group box contains controls for resetting the TLV320AIC3106. A software reset can
be done by writing to a register in the TLV320AIC3106, and this is accomplished by pushing the button
labeled Software Reset. The TLV320AIC3106 also may be reset by toggling a pin on the
TLV320AIC3106, which is done by pushing the Hardware Reset button.
CAUTION
In order to perform a hardware reset, the RESET jumper (JMP19) must be
installed and SW2-7 on the USB-MODEVM must be turned OFF. Failure to do
either of these steps results in not generating a hardware reset or causing
unstable operation of the EVM, which may require cycling power to the
USB-MODEVM.
Below the Firmware box, the Device Connected LED should be green when the EVM is connected. If the
indicator is red, the EVM is not properly connected to the PC. Disconnect the EVM and verify that the
drivers were correctly installed, then reconnect and try restarting the software.
One the upper right portion of the screen, several indicators are located which provide the status of
various portions of the TLV320AIC3106. These indicators are activated by pressing the Indicator
Updates 
button below the Device Connected LED. These indicators, as well as the other indicators on
this panel, are updated only when the software's front panel is inactive, once every 20ms.
The ADC Overflow and DAC Overflow indicators light when the overflow flags are set in the
TLV320AIC3106. Below these indicators are the AGC Noise Threshold Exceeded indicators that show
when the AGC noise threshold is exceeded. To the far right of the screen, the Short Circuit Detect
indicators show when a short-circuit condition is detected, if this feature has been enabled. Below the
short-circuit indicators, the AGC Gain Applied indicators use a bar graph to show the amount of gain
which has been applied by the AGC, and indicators that light when the AGC is saturated.