Texas Instruments TLV320AIC3106 Evaluation Module (EVM) and USB motherboard TLV320AIC3106EVM-K TLV320AIC3106EVM-K Datenbogen

Produktcode
TLV320AIC3106EVM-K
Seite von 58
www.ti.com
TLV320AIC3106EVM Software
4.9
AGC Tab
Figure 11. AGC Tab
The AGC tab (see
consists of two identical sets of controls, one for the left channel and the
other for the right channel. The AGC function is described in the
data sheet.
The AGC can be enabled for each channel using the Enable AGC button. Target gain, Attack time in
milliseconds, Decay time in milliseconds, and the Maximum PGA Gain Allowed can all be set,
respectively, using the four corresponding knobs in each channel.
The TLV320AIC3106 allows for the Attack and Decay times of the AGC to be setup in two different
modes, standard and advanced. The Left/Right AGC Settings button determines the mode selection.
The Standardmode provides several preset times that can be selected by adjustments made to the
Attackand Decayknobs. If finer control over the times is required, then the Advanced mode is selected to
change to the settings. When the Advanced mode is enabled, two tabs should appear that allow separate,
advanced control of the Attack and Delay times of the AGC (see
and
). These options
allow selection of the base time as well as a multiplier to achieve the actual times shown in the
cooresponding text box. The Use advanced settings? button should be enabled to program the registers
with the correct values selected via the pull-down options for base time and multiplier.
19
SLAU209A – April 2007 – Revised June 2010
TLV320AIC3106EVM and TLV320AIC3106EVM-PDK
Copyright © 2007–2010, Texas Instruments Incorporated