Test Setup and Results
lists the R1 values for some common output voltages. For higher output voltages of 1.8 V or
above, a feedforward capacitor (C4) may be required to improve phase margin. Pads for this component
(C4) are provided on the printed-circuit board. Note that the resistor values given in
are standard
values and not the exact value calculated using
.
Table 3. Output Voltages
Output Voltage
R1
R2
C4
L1
C9, C10,
(V)
(k
Ω
)
(k
Ω
)
(pF)
(µH)
C11Total
Capacitance
(µF)
1.0
6.81
22.1
2.2
20 - 68
1.05
8.25
22.1
2.2
20 - 68
1.2
12.7
22.1
2.2
20 - 68
1.5
21.5
22.1
2.2
20 - 68
1.8
30.1
22.1
5 - 22
3.3
20 - 68
2.5
49.9
22.1
5 - 22
3.3
20 - 68
3.3
73.2
22.1
5 - 22
3.3
20 - 68
5.0
124
22.1
5 - 22
4.7
20 - 68
6.5
165
22.1
5 - 22
4.7
20 - 68
3.2
Output Filter and Closed-Loop Response
The TPS54339E relies on the output filter characteristics to ensure stability of the control loop. The
recommended output filter components for common output voltages are given in
. It may be
possible for other output filter component values to provide acceptable closed-loop characteristics. R3 and
TP4 are provided for convenience in breaking the control loop and measuring the closed-loop response.
4
Test Setup and Results
This section describes how to properly connect, set up, and use the TPS54339EEVM-056. The section
also includes test results typical for the evaluation modules and efficiency, output load regulation, output
line regulation, load transient response, output voltage ripple, input voltage ripple, start-up, and switching
frequency.
4.1
Input/Output Connections
The TPS54339EEVM-056 is provided with input/output connectors and test points as shown in
power supply capable of supplying 2 A must be connected to J1 through a pair of 20 AWG wires. The load
must be connected to J2 through a pair of 20 AWG wires. The maximum load current capability is 2 A.
Wire lengths must be minimized to reduce losses in the wires. Test point TP1 provides a place to monitor
the V
IN
input voltages with TP2 providing a convenient ground reference. TP8 is used to monitor the output
voltage with TP9 as the ground reference.
Table 4. Connection and Test Points
Reference Designator
Function
J1
V
IN
(see
for V
IN
range)
J2
V
OUT
, 1.05 V at 3-A maximum.
JP1
EN control. Connect EN to OFF to disable, connect EN to ON to enable.
TP1
V
IN
test point at V
IN
connector.
TP2
GND test point at V
IN
connector.
TP3
EN test point.
TP4
Loop response measurement test point.
TP5
VREG5 test point.
TP6
Switch node test point.
TP7
Analog ground test point.
4
TPS54339EEVM-056, 3-A, Regulator with Eco-Mode™ Evaluation Module
SLVU814 – November 2012
Copyright © 2012, Texas Instruments Incorporated